Transport and Storage
Three Phase Inverter Transport
The Three Phase Inverter should be transported in its original packaging,
facing up and without exposing the Three Phase Inverter to unnecessary
shocks. If the original package is no longer available, a similar box can be
used which can withstand the weight of the Three Phase Inverter (25 kg),
has a handle system and can be closed fully.
Three Phase Inverter Storage
Store the Three Phase Inverter in a dry place where ambient temperatures
are always between -25°C and +60°C.
Equipment List
Standard tools can be used during the installation of the SolarEdge system.
The following is a recommendation of the equipment to be used when
installing a SolarEdge system:
Allen screwdriver for M6 and M5 screw types.
Flat Head screwdriver.
Electrical screwdriver (tester).
Drilling machine and bits suitable for a wall or pole, where the inverter
mounting bracket is installed.
Suitable screws for attaching the inverter mounting bracket to a wall.
M8 screws for attaching the power optimizer to the racking.
Wire cutters.
Wire strippers.
Voltmeter.