SOLARA Zero Clearance MQZDV3318 User Manual Download Page 38

38

Kingsman Fireplace Venting

Kingsman Parts MQZDV3318/3622

Catalog
Number

Description

Valve System Parts  - 

New Top convertible SIT

1000-P136WR

Generator/Thrermopile

1001-P069SI

Electrode Sparker 915.069 TC SIT

1001-P216SI

Thermocouple 290.216 TC SIT 

1001-P165SI

Orifice Pilot NG 977.165 TC SIT

1001-P167SI

Orifice Pilot LP 977.167 TC SIT

1001-P280SI

Tubing 24”

1001-P633SI

Valve Nova LP Hi/Lo   0820651

1001-P634SI

Valve Nova NG Hi/Lo  0820652

1001-P713SI

Pilot Burner LP 199.713 TC SIT

1001-P714SI

Pilot Burner NG 199.714 TC SIT

Miscellaneous Parts

1000-150GE

#Silicone GE Red IS806 #736

1000-150MP

#Hi-Temp Millpac Sealant 840099

1000-214

#Piezo-Igniter 1244-17 MARK 21

1000-215

#Pal Nut (18MMXI.5MM)BLK (1364.03)

1000-218

#Switch Ivory (1451/001)

1000-227

#Cover Ivory (86001/001)

1000-255

#Orifice Brass - (State Size)

6000-130

#Explosion felt Gasket

2000-080

#Thermodisc 2450 (For Blower)

1000-306

Thermalcord - Adhesive Back for Door 

Frame

1000-085

#Control Variable Speed KBWC-13BV

Accessories

Z1MT

Thermostat Millivolt Wall Mount

Z80PT

Thermostat Programmable Digital Millivolt

Wall Mount (1F80-40)

ZIRC

Remote Control Millivolt (On/Off with 

LED)(Model1)

ZART

Remote Control Thermostat Millivolt (Model K)

RMCBN

Remote Control - Basic - Natural Gas

(On/Off,Hi/Lo Flame Adjustment)

RMCBP

Remote Control - Basic - Liquid Propane

(On/Off, Hi/Lo Flame Adjustment)

DCHS

Remote Control Heatshield

VLBIT4

Log Bits - Large Four Piece Kit

VLBIT6

Log Bits - Small Six Piece Kit

Catalog
Number

Description

ZDVHSK

Horizontal Vent Starter Kit - 3 FT Length

Horizontal Vent Termination, Wall Thimble,

36” Flex Pipe, Mill Pac.

ZDVHSK5

Horizontal Vent Starter Kit - 5 FT Length
Horizontal Vent Termination, Wall Thimble,
60” Flex Pipe, Mill Pac.

ZDVHSKSQ

Horizontal Square Termination Vent Starter Kit 

-3 FT Length

Horizontal Vent Termination, Wall Thimble,

Wall Thimble, 36” Flex Pipe, Mill Pac

ZDVHSKSQ5 Horizontal Square Termination Vent Starter Kit 

-5 FT Length

Horizontal Vent Termination, Wall Thimble,

Wall Thimble, 60” Flex Pipe, Mill Pac

FDVHSQ

Horizontal Square Vent Termination

FDVVT40

Vertical Vent Termination converts from     

15’-40’ to 15’ and under

FDVHT

Horizontal Vent Termination

FDVHSQ

Horizontal Square Termination

ZDVST

Horizontal Snorkel Termination
(34” Tall, 24” Center to Center)

FDVHSCU

Safety Cage for Horizontal Termination

ZDVAIS

Attic Insulation Shield

ZDVVOS

Offset Support

ZDVFS

Firestop Spacer

ZDVRS

Roof Support

ZDVWT

Wall Thimble (Horizontal Venting)

ZDVSSLR

Siding Shield - Large Return

ZDV48GP

Galvanized Pipe 7” Dia. x 48” (Vertical 
Installations)

ZDVAAF

Flashing 7” c/w Storm Collar (1/12 to 7/12)

ZDVAF2

Flashing 7” c/w Storm Collar (8/12 to 12/12)

ZDVAF3

Flashing 7” c/w Storm Collar Flat

ZDV7SC

Storm Collar 7”

ZDVFK5

Flex Kit (4” & 7” Dia.) x 2.5’ (Unexpanded) 5’ 
Expanded

ZDVFK8

Flex Kit (4” & 7” Dia.) x 4’ (Unexpanded) 8’ 
Expanded

ZDVFK20

Flex Kit (4” & 7” Dia.) x 10’ (Unexpanded) 20’ 
Expanded
*Kits are complete with spring stand-offs, silicone.

ZDV4FC

Flex Connector 4” Diameter

ZDV7FC

Flex Connector 7” Diameter

ZDV4SS

Spring 4” Standoff Spacer

ZDVDFA

Dura-Vent Fireplace Adapter
(for ZDV33/36/42/47, ZDV6000, MDV30/38 & 
HB models)

Summary of Contents for Zero Clearance MQZDV3318

Page 1: ...vice or maintenance can cause property damage personal injury or loss of life Refer to this manual Installation and service must be performed by a qualified installer service agency or the gas supplie...

Page 2: ...wn between each Be aware during log and firebox paint curing that a white deposit may be developing on the inside of the glass doors It is important to remove this white deposit from the glass doors w...

Page 3: ...es Specifications 16 Dimensions Installation of Wall Mount Surrounds 17 Fan Installation 18 Brick Installation 19 Porcelain Panel Installation Guide 20 General Glass Information 21 Gas Line Installati...

Page 4: ...LED IN MANUFACTURED MOBILE HOMES Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded...

Page 5: ...iately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water 12 WARNING Do not operate appliance with t...

Page 6: ...terminal must be used and if applicable a Product approved air intake must be used Installation shall be in strict compliance with the manufacturer s instructions A copy of the installation instructi...

Page 7: ...d installation with a top vent is possible as long as the hori zontal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall c...

Page 8: ...ust be raised a minimum of 2 7 8 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the fireplace to the cei...

Page 9: ...9 Z33CVCK Framing and Facing Requirements MQZDV3318 WITH Z33CVCK CLEAN VIEW CIRCULATING KIT Z33CVCK with Wall Surround...

Page 10: ...nd installation with a top vent is possible as long as the hori zontal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall...

Page 11: ...the fireplace must be raised a minimum of 2 1 2 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the firep...

Page 12: ...12 Z36CVCK Framing and Facing Requirements MQZDV3622 WITH Z36CVCK CLEAN VIEW CIRCULATING KIT Z36CVCK with Wall Surround...

Page 13: ...hers skip to Step 4 Using screws provided fasten the non combustible header onto the top of CVCK assembly 4 Hang CVCK onto top of fireplace retainer tabs and rotate into position Fig 2 5 Using 4 suppl...

Page 14: ...MQZDV3318 3622 Mantels Surrounds Warning Combustible objects must not be placed on a non combustible mantel unless the non combustible mantel meets the minimum height and width requirements for a comb...

Page 15: ...o or over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top...

Page 16: ...ance For units with CVCK Clear View Circulating Kit see framing with CVCK to establish floor heights MQZDV3622 Clearance to Combustibles Clearance to Combustibles Back from Standoffs 0 inches 0 mm Sid...

Page 17: ...G 8 3 4 8 3 4 H 1 1 I 1 3 16 1 3 16 1 Set Surround Lip on CVCK Ledge and ensure that it is securely in place 2 Swing the upper portion of the Surround so that the Surround Ledge is resting on top of t...

Page 18: ...o 120v Install a duplex outlet to junction box and plug fan into outlet 4 Turn the wall switch on clockwise Turn fireplace on Once the sensor in the unit reaches operating temperature approximately 10...

Page 19: ...firebox When placing Panel tilt panel towards you and lift panel over the burner assembly Fig 2 5 To place side Liner Panels rotate panel towards you and place bottom edge of panel over the front ledg...

Page 20: ...e panel tilt it towards you while lifting it over the burner assembly 5 To place the side liner panels rotate it towards you while placing the bottom edge over the front ledge of the firebox Then rota...

Page 21: ...ed fittings Always pro vide a union so that gas line can be easily disconnected for burner or fan servic ing See gas specification for pressure details and ratings 4 When a vertical section of gas pip...

Page 22: ...oval Instructions 2 Disconnect gas line connection at burner system through access cover opening 3 Remove extension knobs and wiring from face of gas valve 4 Remove screws from perimeter of burner sys...

Page 23: ...pilot screw to provide proper sized flame Caution Do Not Wire 120 Volt PowerTo Millivolt Switches Or Thermostats Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire...

Page 24: ...etting Loosen screw on the side of air mixing tube and rotate to the correct opening using a dirll bit or tape measure Tighten screw 7 After converting parts to the new type of gas reverse all step s...

Page 25: ...amped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove 5 Refer to the Appliance Manufacture...

Page 26: ...rminals at wall switch If burner comes on replace Switch ON defective wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connec tions are bad Gen...

Page 27: ...glowing rock wool on burner as shown in step 1 being sure to leave the multiple porting areas open For Lp only the multiple porting areas can be completely covered Do not cover the Rear Porting areas...

Page 28: ...ectly over top of the multiple porting area on the left side Step 5 Fill in the rest of the burner pan and ember plates with lava rock and vermiculite Do not place lava rock or vermiculite on any of t...

Page 29: ...ove the 2 ember plates once the grate bar is removed The 2 screws removed must be re installed once the grate bar is removed Step 3 Using the left ember plate mounting bracket slide the left ember pla...

Page 30: ...ure that they are crossing over the single line porting MQRSP5 finished setup and burn Step 8 Place rock 3 and rock 1 into position as shown to complete the setup Lava rock and vermiculite are optiona...

Page 31: ...fami ly dwellings and serves both dwellings 4 Permitted only if veranda porch deck or balcony is fully open on a minimum of two sides beneath the floor 5 Clearance in accordance with local installati...

Page 32: ...e Venting Kingsman Flex pipe is shipped in unexpanded length When installing pipe expand the lengths Pipe can be expanded to twice their lengths e g 4ft to 8ft Fully expand pipe and cut off excess Do...

Page 33: ...ght of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal verti...

Page 34: ...assing through a ceiling or floor If an attic insulation shield is to be used a fire stop is not required Roof Flashing Ensure that you have the proper roof flashing by checking your roof pitch using...

Page 35: ...IR INTAKE ADJUSTMENT PLATE NOTE Unit comes preset for short horizontal or vertical venting under a 15 feet run Follow these instructions when venting exceeds 15 foot run 1 Locate the 3 x 1 4 hex screw...

Page 36: ...Surround Slim Line Antique Brass Z33SLCR Surround Slim Line Chrome Z33SLPB Surround Slim Line Polish Brass Z33SLBL Surround Slim Line Gun Metal Black Designer Doors for 33 Fireplaces Operative Z33DDA...

Page 37: ...AB Surround Slim Line Antique Brass Z36SLCR Surround Slim Line Chrome Z36SLPB Surround Slim Line Polish Brass Z36SLBL Surround Slim Line Gun Metal Black Designer Doors for 36 Fireplaces Operative Z36D...

Page 38: ...iece Kit Catalog Number Description ZDVHSK Horizontal Vent Starter Kit 3 FT Length Horizontal Vent Termination Wall Thimble 36 Flex Pipe Mill Pac ZDVHSK5 Horizontal Vent Starter Kit 5 FT Length Horizo...

Page 39: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...