If fireplace has been installed with optional CVCK (Clean View Circulating Kit) to service fan system or burner system controls, the access cover and
burner system pan will have to be removed.
Access Cover Removal
1.
Remove door, logs, brick panels, burner grate, rock platform and burner from firebox.
2.
Burner grate or optional rock platform are fastened by 2 screws. There is one right and one left assembly Remove screws and take out grate or
rock platform.
3.
Remove Log Support Plates right and left of burner, log support plates are loose and not fastened in place.
4.
Loosen screws from burner retainer tabs and slide burner to the left to remove from orifice.
5.
Remove 10 screws holding access cover in place. Push down on one corner of access cover to break seal of cover. Once loose cover can be slid
under firebox bottom to expose gas connection.
*CAUTION ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN
Removing Burner System
1.
Complete all steps in Access Cover Removal Instructions.
2.
Disconnect gas line connection at burner system through access cover opening.
3
Remove extension knobs and wiring from face of gas valve.
4.
Remove screws from perimeter of burner system pan. Lift pan at one back corner and rotate pan up from back of firebox. Make sure, when tilt-
ing up and removing burner system that all fan and valve control wiring is disconnected at this time.
To re-install access cover/burner system. Remove old Mil Pac sealant and apply new sealant. After new sealant is applied, reverse removal pro-
cedure to re-install parts.
22
Burner System Removal for MQZDV3318/3622
MQZDV3318 /3622 Fireplace
MQZDV3318 /3622 Burner System
*CAUTION BEFORE STARTING REMOVAL OF PARTS TURN OFF GAS SUPPLY. DISCONNECT 110 VOLTS TO FAN SYSTEM
AND DISCONNECT 110 VOLTS TO ELECTRONIC IGNITION BURNER SYSTEM IF APPLICABLE
*Caution high temperature sealant has been applied to access cover and burner system pan. New sealant will have to be applied when re-
installing access cover and burner system to maintain the integrity of the sealed combustion chamber. Mil Pac part #840099 or Kingsman
part # 100-15MP sealant can be purchased from your Kingsman retailer or distributor.