FIGURE 1

FIGURE 2

MINIMUM OF
1.0" TO
COMBUSTIBLES

31.0”

MINIMUM

FOR ZDV3318

33.0"

MINIMUM

FOR ZDV3622

COMBUSTIBLE AIR INLET

FLUE GAS OUTLET

FRAMING DETAIL

11.0"

11.0"

8" DIA

31.0" TO CENTERS MINIMUM FOR ZDV3318
33.0" TO CENTERS MINIMUM FOR ZDV3622

THROUGH COMBUSTIBLE
WALL

THROUGH 
NON-COMBUSTIBLE WALL

NOTE:  See Pages
7,10 and 31 for
proper framing
dimensions.

General Vent Installation Information

Installation Of Side Wall Venting

1. To determine the minimum distance from the bottom of fireplace to centre of vent see page

7 for the MQZDV3318 and page 10 for the MQZDV3622.  Cut a hole through the wall

allowing for a 11” x 11” (inside diameter) in combustible walls for wall thimble or an 8”

diameter hole in a non-combustible wall (See Figure 2).

2. For the clearance to combustible above a 90 degree bend see page 15.
3. Select the approximate vent length, precise measurements are not needed as your flex pipe

can be expanded to twice its shipped length for ease of installation.

4. To install wall thimble centre over 11” x 11” (inch) framing from both sides of wall and

secure.  Route flex vent pipe through wall thimble (See Figure 1).

5. Before joining pipes, apply a bead of high temperature sealant (Mill Pac) to end of pipe.

First attach the four inch (4”) flue pipe to the vent termination with sealant,  and secure with

the four screws provided. At this time make sure the spacer springs are attached to the (4”)

flex pipe as required.  Then attach the seven inch (7”) pipe by the same method.

6. Mount vent termination and seal to wall using caulking around the wall thimble to weather

proof.  After installing the vent termination, double check to make sure the pipe extends

properly through wall thimble and into vent termination.

7. Before joining pipes to fireplace flue, apply a bead of high temperature sealant (Mill Pac) to

end of pipe.  First attach the four inch (4”) flue pipe to fireplace with sealant,  and secure

with the four screws provided.  At this time verify that the spacer springs are attached prop-

erly to the (4”) flex pipe as required.  Then attach the seven inch (7”) pipe by the same

method.

8. Support horizontal pipes every two (2) feet (61 cm) with metal strap bands.  Re-check fire-

place to make sure it is levelled and properly positioned and secured.

9. Support vertical pipes to maintain a minimum of 1” or greater clearance to combustibles

with metal strapping bands.

10. If finishing the outside wall with vinyl or wood siding it is recommended that a Siding

Shield be installed, Part Number ZDVSSLR.

Note: Vent Termination must not be recessed into wall or siding.

RIGID OR HARD PIPE

When using Simpson Duravent, AmeriVent pipe, ICC Excel Direct, Metal Fab Sure-Seal DV and
or Selkirk Direct Temp a Duravent hardpipe adapter must be used (p

part # ZDVDFA  for fireplaces

and part # ZDVDKA for Stoves, Serenity and ZDV3624B). Follow installation instructions provid-
ed by Simpson Duravent/AmeriVent/Selkirk Direct Temp, ICC Excel Direct, Metal Fab Sure-Seal
DV for installation of pipe and adhere to the clearance to combustibles provided in this manual.
Apply a bead of Mill Pac high temp sealant to all joints of pipes, adapters and termination, when
using Kingsman Flex(Z-Flex)Venting venting and Simpson Duravent venting. 

NOTE:

Increase framing depth by one inch when using hardpipe.

Flex Pipe Venting

Kingsman Flex pipe is shipped in unexpanded length. When installing pipe expand the lengths.
Pipe can be expanded to twice their lengths e.g. 4ft. to 8ft. Fully expand pipe and cut off excess.
Do not use more than 2 couplers to extend short pipes. Single sections are preferred in an installa-
tion attaching at the fireplace and termination.
Place the spring spaces provided approximately every two feet to stabilize 4” flex in the center of 7”
flex. When forming bends place spring in bend or before and after. (See Fig. 1).
Horizontal runs require support metal straps every 2 feet. In off set installation support straps
should be used to stabilize pipe.
Expand 4” and 7” flex pipe to the point that the 7” protrudes approximately 2 to 3 inches past outer
wall and the 4” flex protrudes approximately 2 to 3 inches past the 7” flex. See Fig. 1. Attach the 4”
pipe to the termination first and secure with sealant and screws then attach the 7” flex to the termina-
tion with caulking and screws. Termination may then be moved back to the outer wall and attached
to home screwing into the framing. Silicone around termination to waterproof. If siding shield is
going to be used attach this using same attaching hole as the top of termination after termination has
been caulked for water proofing.

Use Hi Temp Sealant

Apply a bead of mill pac high temp sealant to all joints and use four screws to secure each pipe at
fireplace, termination and any joint if joining any sections of pipe.

NOTE: 

It is critical to the proper and safe operation of

this fireplace that on all connections the inner liner and
the outer casing are both caulked with liberal amounts of

sealant. Do not use any kind of tape or silicone other than
that recommended in this manual, Mill Pac Sealant

FRAMING DIMENSION
Combustible Wall

Cut a 11” hole through exterior wall and frame as shown

below.

Non combustible Wall

Cut or drill 8” or 204mm diameter hole.

OPTIONAL
CLAMPS

FIGURE 1

MAX. DISTANCE BETWEEN SPACERS 2 FEET
SPRING SPACERS

OPTIONAL
CLAMPS

SEAL WITH HIGH TEMP. SEALANT

SEAL WITH HIGH TEMP. SEALANT

WARNING: 

DO NOT mix parts from different systems unless stated in the manual.

This gas appliance is approved to be vented either through the side wall or vertically through the roof.  

Only Kingsman Flex(Z-Flex)Venting Kits and com-

ponents specifically approved and LABELED for this stove may be used

.  This appliance is also approved for use with Simpson-Duravent Direct Vent sys-

tem (Model DV-GS Series), Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.

Simpson Dur a-Vent for  Masonr y Chimney Conver sion Kits may be used with this appliance Use your existing masonry chimney and route the
exhaust gases intake air through the side of the masonry chimney. Use Simpson Dura-Vent kit numbers 46DVA-KMC or 46DVA-KCT.
Termination Cap, Kingsman/Dura-Vent adapter, and 4” flex are sold separately.

Simpson Dur a-Vent for  Factor y built metal Chimney Conver sion Kits may be used with this appliance. Use your existing through the ceiling,
wood stove chimney and route the exhaust gases and intake air through the existing wood burning metal chimney. Use Simpson Dura-Vent Kit
numbers 46DVA-KCA for 6 5/8” to 8 5/8” OD sized chimney, 46DV-KCB for 8 3/4” to 10 1/2” OD sized chimneys and 46DVA-KCC for 10 5/8”
to 13” OD sized chimneys. Kits 931, 932, and 933 include a cap adapter and Retro Connector. Termination Cap, Kingsman/Dura-Vent adapter, and
4” flex are sold separately.

Summary of Contents for Zero Clearance MQZDV3318

Page 1: ...vice or maintenance can cause property damage personal injury or loss of life Refer to this manual Installation and service must be performed by a qualified installer service agency or the gas supplie...

Page 2: ...wn between each Be aware during log and firebox paint curing that a white deposit may be developing on the inside of the glass doors It is important to remove this white deposit from the glass doors w...

Page 3: ...es Specifications 16 Dimensions Installation of Wall Mount Surrounds 17 Fan Installation 18 Brick Installation 19 Porcelain Panel Installation Guide 20 General Glass Information 21 Gas Line Installati...

Page 4: ...LED IN MANUFACTURED MOBILE HOMES Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded...

Page 5: ...iately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water 12 WARNING Do not operate appliance with t...

Page 6: ...terminal must be used and if applicable a Product approved air intake must be used Installation shall be in strict compliance with the manufacturer s instructions A copy of the installation instructi...

Page 7: ...d installation with a top vent is possible as long as the hori zontal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall c...

Page 8: ...ust be raised a minimum of 2 7 8 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the fireplace to the cei...

Page 9: ...9 Z33CVCK Framing and Facing Requirements MQZDV3318 WITH Z33CVCK CLEAN VIEW CIRCULATING KIT Z33CVCK with Wall Surround...

Page 10: ...nd installation with a top vent is possible as long as the hori zontal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall...

Page 11: ...the fireplace must be raised a minimum of 2 1 2 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the firep...

Page 12: ...12 Z36CVCK Framing and Facing Requirements MQZDV3622 WITH Z36CVCK CLEAN VIEW CIRCULATING KIT Z36CVCK with Wall Surround...

Page 13: ...hers skip to Step 4 Using screws provided fasten the non combustible header onto the top of CVCK assembly 4 Hang CVCK onto top of fireplace retainer tabs and rotate into position Fig 2 5 Using 4 suppl...

Page 14: ...MQZDV3318 3622 Mantels Surrounds Warning Combustible objects must not be placed on a non combustible mantel unless the non combustible mantel meets the minimum height and width requirements for a comb...

Page 15: ...o or over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top...

Page 16: ...ance For units with CVCK Clear View Circulating Kit see framing with CVCK to establish floor heights MQZDV3622 Clearance to Combustibles Clearance to Combustibles Back from Standoffs 0 inches 0 mm Sid...

Page 17: ...G 8 3 4 8 3 4 H 1 1 I 1 3 16 1 3 16 1 Set Surround Lip on CVCK Ledge and ensure that it is securely in place 2 Swing the upper portion of the Surround so that the Surround Ledge is resting on top of t...

Page 18: ...o 120v Install a duplex outlet to junction box and plug fan into outlet 4 Turn the wall switch on clockwise Turn fireplace on Once the sensor in the unit reaches operating temperature approximately 10...

Page 19: ...firebox When placing Panel tilt panel towards you and lift panel over the burner assembly Fig 2 5 To place side Liner Panels rotate panel towards you and place bottom edge of panel over the front ledg...

Page 20: ...e panel tilt it towards you while lifting it over the burner assembly 5 To place the side liner panels rotate it towards you while placing the bottom edge over the front ledge of the firebox Then rota...

Page 21: ...ed fittings Always pro vide a union so that gas line can be easily disconnected for burner or fan servic ing See gas specification for pressure details and ratings 4 When a vertical section of gas pip...

Page 22: ...oval Instructions 2 Disconnect gas line connection at burner system through access cover opening 3 Remove extension knobs and wiring from face of gas valve 4 Remove screws from perimeter of burner sys...

Page 23: ...pilot screw to provide proper sized flame Caution Do Not Wire 120 Volt PowerTo Millivolt Switches Or Thermostats Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire...

Page 24: ...etting Loosen screw on the side of air mixing tube and rotate to the correct opening using a dirll bit or tape measure Tighten screw 7 After converting parts to the new type of gas reverse all step s...

Page 25: ...amped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove 5 Refer to the Appliance Manufacture...

Page 26: ...rminals at wall switch If burner comes on replace Switch ON defective wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connec tions are bad Gen...

Page 27: ...glowing rock wool on burner as shown in step 1 being sure to leave the multiple porting areas open For Lp only the multiple porting areas can be completely covered Do not cover the Rear Porting areas...

Page 28: ...ectly over top of the multiple porting area on the left side Step 5 Fill in the rest of the burner pan and ember plates with lava rock and vermiculite Do not place lava rock or vermiculite on any of t...

Page 29: ...ove the 2 ember plates once the grate bar is removed The 2 screws removed must be re installed once the grate bar is removed Step 3 Using the left ember plate mounting bracket slide the left ember pla...

Page 30: ...ure that they are crossing over the single line porting MQRSP5 finished setup and burn Step 8 Place rock 3 and rock 1 into position as shown to complete the setup Lava rock and vermiculite are optiona...

Page 31: ...fami ly dwellings and serves both dwellings 4 Permitted only if veranda porch deck or balcony is fully open on a minimum of two sides beneath the floor 5 Clearance in accordance with local installati...

Page 32: ...e Venting Kingsman Flex pipe is shipped in unexpanded length When installing pipe expand the lengths Pipe can be expanded to twice their lengths e g 4ft to 8ft Fully expand pipe and cut off excess Do...

Page 33: ...ght of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal verti...

Page 34: ...assing through a ceiling or floor If an attic insulation shield is to be used a fire stop is not required Roof Flashing Ensure that you have the proper roof flashing by checking your roof pitch using...

Page 35: ...IR INTAKE ADJUSTMENT PLATE NOTE Unit comes preset for short horizontal or vertical venting under a 15 feet run Follow these instructions when venting exceeds 15 foot run 1 Locate the 3 x 1 4 hex screw...

Page 36: ...Surround Slim Line Antique Brass Z33SLCR Surround Slim Line Chrome Z33SLPB Surround Slim Line Polish Brass Z33SLBL Surround Slim Line Gun Metal Black Designer Doors for 33 Fireplaces Operative Z33DDA...

Page 37: ...AB Surround Slim Line Antique Brass Z36SLCR Surround Slim Line Chrome Z36SLPB Surround Slim Line Polish Brass Z36SLBL Surround Slim Line Gun Metal Black Designer Doors for 36 Fireplaces Operative Z36D...

Page 38: ...iece Kit Catalog Number Description ZDVHSK Horizontal Vent Starter Kit 3 FT Length Horizontal Vent Termination Wall Thimble 36 Flex Pipe Mill Pac ZDVHSK5 Horizontal Vent Starter Kit 5 FT Length Horizo...

Page 39: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Reviews: