TESTING THE BATTERY
After fully charging the battery (see “Recharging” section), apply a 100 amp load to the
unit for a period of 6 seconds, while monitoring the battery voltage. The battery is good
if the voltage is 9.5 VDC or higher.
BATTERY REMOVAL AND DISPOSAL INSTRUCTIONS
CONTAINS SEALED LEAD-ACID BATTERY.
BATTERY MUST BE RECYCLED.
The battery inside this product is a sealed lead-acid battery. It is
required by law
to be removed and recycled or disposed of properly. While there
are federal regulations that must be complied with throughout the United States, your
individual state or local governments may have additional regulations to be followed.
When the battery in this product is in need of replacement, remove it according to
the instructions provided below and take it to your local recycling center for proper
recycling or disposal. If you don’t have a local recycling center that handles sealed
lead-acid batteries, contact your local environmental agency for instructions.
Removal Instructions
Begin by making sure that both clamps are securely stowed in their holsters on each
side of the CS2000.
1. Lay the CS2000 down on its front. On the back of the unit, locate the four
screws that hold the case together (two along the left edge and two along the
right edge).
2. Remove the four screws, then lift off the back half of the case.
3. On the top of the battery are two terminals, each with wires connected to them.
Disconnect these wires from the battery by removing the bolts that hold them to
the battery terminals. To prevent accidental arcing, be careful not to touch both
battery terminals with the tools being used to remove the bolts.
4. Lift the battery out of the front half of the case.