81
December 2020
|
Solar Stik
®
, Inc.
SYSTEM SETUP AND OPERATION GUIDE FOR THE SOLAR STIK USAF G-BOSS MEDIUM AND HEAVY HYBRID POWER SYSTEM
PRELIMINARY DRAFT
Item #
Item to be
Inspected
Interval
Procedures
Non-mission Capable
1
Visual
inspection of
24VDC PRO-
Verter 5000
M
1. Inspect case for visible damage
and missing items.
2. Clean excessive dust or dirt
accumulation from the exterior,
interior and connectors.
3. Close all unused port covers.
~If the case is broken or split or
if connectors are damaged, do
not place into service.
2
Air Intake
Filters
M
1
1. Remove the three (3) air intake
vent covers to expose the filter
material. (See PRO-Verter Manual
for location of air intake filters.)
2. Wash with water and dry the filter.
Reinstall.
3. If the filter is damaged or cannot
be cleaned replace.
~If the filter cannot be cleaned,
is too damaged to function
properly and a replacement is
not immediately available, the
unit is partially mission capable.
Replace the filter as soon as
possible to restore the unit to
fully mission capable.
1
Clean or replace more frequently when the System is operating in dusty, windy environments
Table 6. 24VDC PRO-Verter 5000-120 PMCS
24VDC PRO-Verter 5000-120 PMCS
1. Use a #2 cross-tip screwdriver to remove the four (4) fasteners from the vent shroud (Figure 26)
and remove the louvered vent cover to access the filter.
Figure 26. Fastener locations on vent shroud (upgraded/new
version)
Figure 27. Removed vent shroud to access the
louvered vent cover
PRO-Verter Air Intake Filter Removal and Cleaning or Replacement