December 2020
|
Solar Stik
®
, Inc.
30
|
SYSTEM SETUP AND OPERATION GUIDE FOR THE SOLAR STIK USAF G-BOSS MEDIUM AND HEAVY HYBRID POWER SYSTEM
PRELIMINARY DRAFT
AC IN and AC OUT Breakers
—Circuit breakers protect against overcurrent conditions in dedicated
circuits. If too much amperage flows due to short-circuit, inadequate or improper loading, or
component failure, these will protect the System and Operator. The LED associated with the breaker
is green when there is power to the breaker from an AC power source. The LED will be illuminated
even when the breaker is in the OFF position.
24 VDC 5 A Output and Breaker
—These terminal posts supply power to the RMK if present. The
LED associated with the breaker is green when the circuit is operating normally.
Remote Monitoring Kit (RMK)
—This optional (sold separately) device reports, records, and stores
28 PRO-Verter and System metrics.
RMK Connection Ports and Cables
—These port and cables provide communication connections
between the RMK, the PRO-Verter, and remote access monitoring equipment (via the Tech Port).
System Recovery Switch
—This switch provides a way to restart a System using 120 VAC power
if the System batteries are overdischarged/there is no 24 VDC power source available. See
Recovery to Restore Overdischarged Batteries
section.
AC Input Reverse Polarity Indicator LED
—LED will light red when reverse polarity is sensed on
the AC input.
USB Charging Ports (x2)
—Provides 5 VDC / 2.1 A. Charging only. No data.