background image

SCU.VDR03.BLG14

SCU.VDR03.BLG34

TECHNICAL INSTRUCTIONS

Supply and command central unit

 video door system

4 WIRE

for buildings with 1 – 5 Families

EN

Summary of Contents for Touch Line SCU.VDR03.BLG14

Page 1: ...SCU VDR03 BLG14 SCU VDR03 BLG34 TECHNICALINSTRUCTIONS Supply and command central unit video door system 4 WIRE for buildings with 1 5 Families EN ...

Page 2: ...Line video door systems with 4 or 5 Families 5 1 Connections for separate powered AC lock max 3A 5 2 Connections for separate powered DC lock max 3A 5 3 Connections for separate powered impulse control DC lock max 3A 5 4 Connections for internal powered DC lock in the 14 GND terminals of the SCU max 0 6A 6 Connection of auxiliary installations 7 Connection of Digital Video Recorder DVR 8 Programmi...

Page 3: ...unting or service 3 DO NOTTOUCH the metallic parts of the wires or the connection terminals of the central unit SCU or of the fuses First you have to unplug the cable from the socket and then you can workwith the central unit SCU 4 ATTENTION Do not supplycomponents of the installation separately outdoor panel terminals etc from other power supplies or directlyfrom the network 110 230Vc a 50 60Hz R...

Page 4: ...for opening the door gate from the inside home yard Video recording devices DVR Rechargeable battery 12Vd c 12Ah 4 The system programming mode is set and reset by pressing the PROG button The programming mode is signaled by the red PROG LED 5 Diagnosis with light signals network 14 supply voltage battery status shortcircuit at the terminals shortcircuit at the additional video camera shortcircuit ...

Page 5: ...D Vout Recommended cables for the Touch Line video door systems 3 EN 3 Recommended installation cables 2 4 wires x0 5 mm type H03VV F4G 0 5 for max 60 ml 2 4 wires x0 75 mm type H05VV F4G 0 75 for max 100 ml Significance of the connections 14V the connection for power supplying the system components 12 14V C D the connection for audio communication analog and digital data transmission CAN GND the c...

Page 6: ...4 CD GND Vin1 GNV EXIT EXIT LCK LCK NO NC 10 SEC BAT BAT FUSE T1 6A 2 SEC AC 110 230V Vcam Outdoor panel CAM switch 0 without additional video camera 1 with additional video camera DVR switch without DVR video recording on the DVR 0 1 Note The Fam 1 terminal is programmed from the factory with address 1 Grounded socket 110 230Va c 50 60Hz Important 14 C D GND Vin Fam 1 address 1 SCU Terminal Centr...

Page 7: ... address 1 14 C D GND Vin 14 C D GND Vin Note The Fam 1 terminal is programmed from the factory with address 1 The Fam 2 terminal must be programmed with address 2 The Fam 3 terminal must be programmed with address 3 Outdoor panel SCU Terminals GONG DOORBELL Central unit type SCU VDR03 BLG34 Fam 2 address 2 GONG DOORBELL Fam 3 address 3 GONG DOORBELL Vcam Connections for theTouch Linevideo door sy...

Page 8: ...the DVR 0 1 SCU Central unit type SCU VDR03 BLG14 EN 6 14 OTHERVIDEOCAMERA DVR AUX1 AUX2 OUT1 OUT2 OUT3 Vout3 GND CD 14 Vout2 GND CD 14 Vout1 GND CD 14 GNV AUX2 AUX2 AUX1 AUX1 OFF ON GNV Vout 12 GND Vin2 OFF ON AUX1 BAT DOOR LOCK LOCK SUPPLY VIDEO DOOR PANEL 14 CD GND Vin1 GNV EXIT EXIT LCK LCK NO NC 10 SEC BAT BAT FUSE T1 6A 2 SEC AC 110 230V Vcam Grounded socket 110 230Va c 50 60Hz Important max...

Page 9: ...ess 3 The Fam 4 terminal must be programmed with address 4 The Fam 5 terminal must be programmed with address 5 EN 7 Fam 2 address 2 GONG DOORBELL 14 C D GND Vin Fam 4 address 4 GONG DOORBELL 14 C D GND Vin 14 C D GND Vin Fam 1 address 1 GONG DOORBELL Fam 3 address 3 GONG DOORBELL 14 C D GND Vin Fam 5 address 5 GONG DOORBELL 14 C D GND Vin 14 C D GND Vin VCB 4DN03 BLG04 ...

Page 10: ...k 12 24V max 3A 12 24V max 3A Transformer 2 2 x 0 75 mm 2 2 x 0 75 mm 2 2 x 0 5 mm Important Grounded socket 110 230Va c 50 60Hz LCK IMPORTANT A separate transformer 12 24V max 3A will be connected at the LOCK SUPPLY terminals The AC lock 12 24V max 3A will be connected at the LCK1 LCK2 terminals Valid for all types of Touch Line installations Outdoor panel SCU EN 8 14 NC NO LCK LCK LCK LCK 2 sec ...

Page 11: ...PPLY terminals The DC lock 12 24V max 3A will be connected at the LCK1 LCK2 terminals Valid for all types of Touch Line installations 12 24V max 3A Outdoor panel LCK 2 2 x 0 75 mm Important Grounded socket 110 230Va c 50 60Hz BAT DOOR LOCK LOCK SUPPLY VIDEO DOOR PANEL 14 CD GND Vin1 GNV EXIT EXIT LCK LCK NO NC 10 SEC BAT BAT FUSE T1 6A 2 SEC AC 110 230V 14 SCU NC NO LCK LCK LCK LCK 2 sec 10 sec EN...

Page 12: ...0V 14 Connections for separate powered impulse control DClock max 3A 5 3 Valid for all types of Touch Line installations Lock 14 C D GND Vout 2 2 x 0 5 mm IMPULSE 14 C D GND Vin1 12 24V max 3A Outdoor panel Important Grounded socket 110 230Va c 50 60Hz EXIT 2 2 x 0 75 mm 2 1 x 0 5 mm EN 10 SCU NC NO LCK LCK LCK LCK 2 sec 10 sec ...

Page 13: ... terminals of the VIDEO DOOR PANEL connector through 2 wires The DClock 12V max 0 6A will be connected at the LCK1 LCK2 terminals Valid for all types of Touch Line installations Outdoor panel LCK 2 2 x 0 5 mm 2 2 x 0 5 mm SCU BAT DOOR LOCK LOCK SUPPLY VIDEO DOOR PANEL 14 CD GND Vin1 GNV EXIT EXIT LCK LCK NO NC 10 SEC BAT BAT FUSE T1 6A 2 SEC AC 110 230V 14 NC NO LCK LCK LCK LCK 2 sec 10 sec EN 11 ...

Page 14: ...ouch Line terminal The AUX1 AUX2 contacts will close for 2 seconds and sustain a maximum current of 0 5A 2 sec 12 24V 0 5A to the 1st additional installation EN 12 Vin2 OTHER VIDEO AUX 1 AUX 1 AUX 2 AUX 2 BAT AUX1 AUX2 BAT to the 2nd additional installation OTHERVIDEOCAMERA DVR AUX1 AUX2 OUT1 OUT2 OUT3 Vout3 GND CD 14 Vout2 GND CD 14 Vout1 GND CD 14 GNV AUX2 AUX2 AUX1 AUX1 OFF ON GNV Vout 12 GND V...

Page 15: ...0001 2 The address of outdoor panels 2 3 or 4 when the system has additional outdoor panels The programming is done following the procedure in the video panels manual All panels are programmed in the factory with Address 1 3 The storage deletion addition of the RFID access CARDS according to the procedure in the video panels manual Exiting programming mode is done by short pressing the PROG button...

Page 16: ...evideo image Checkthe accuracyof the connections between the SCU central unit and the outdoor panel 6 Aterminal does not function The red OUT1 OUT2 or OUT3 LED indicates a shortcircuit on the corresponding terminal Checkthe accuracyof the connections between the SCU central unit and the terminals 7 The terminals do no function the PROG LED is red Checkthe continuityand the accuracyof the C D conne...

Page 17: ... to reprogram alreadystored RFID cards you will need to remove the EEPROM memoryfrom the defective SCU central unit and insert it into the newSCU central unit replacing the existing one When fixing the EEPROM memory it is mandatoryto keep the same position of the first pin ATTENTION EN 15 ...

Page 18: ... RFID access cards tags which are considered consumables For complaints during the warrantyperiod please contact the companyfrom which you have purchased the product The manufacturer ELECTRAs r l declares that The products are in compliance with the harmonised legislation of the European Union regarding the directives LowVoltage LVD 2014 35 Electromagnetic compatibility EMC 2014 30 EC RoHS 2011 65...

Page 19: ......

Page 20: ...s contain UL compliant printed circuit boards Certificate by R 709 ICPE BELLCOME is a trademark of ELECTRA Group No 013502646 EUIPO Alicante Spain BELLCOME ELECTRA products are registered as Industrial Models EUIPO Alicante Spain SUPPORT ELECTRA Building Communications GmbH Bischoffgasse 5 3 4 1120 Wien AT 43 1 810 20 99 support bellcome com www bellcome com MADE in EU by ELECTRA s r l Parc Industr...