Connections for internal powered DC lock in the +14/ GND terminals
of the SCU (max. 0.6A)
5.4
12V
0.6
A max.
+14
C/D
GND
Vout
EXIT
Lock
IMPORTANT
: The
LOCK SUPPLY
terminals (+/- ) will be connected at the
+14
and
GND
terminals of the
VIDEO DOOR PANEL
connector through 2 wires. The DC lock =12V, max. 0.6A, will be connected at the
LCK1
,
LCK2
terminals.
Valid for all types of
Touch Line
installations.
Outdoor panel
LCK
2
2 x 0,5 mm
2
2
x 0,5 mm
SCU
BAT
DOOR LOCK
LOCK
SUPPLY
VIDEO DOOR PANEL
+14
CD
GND
Vin1
GNV
EXIT
EXIT
LCK
LCK
NO
NC
10 SEC
BA
T
BA
T
FUSE - T1.6A
2 SEC
AC. 110/230V
+14
NC -
NO -
LCK
LCK
LCK
LCK
2 sec.
10 sec.