C/D
6mm
25-30mm
GND
Vin
+14V
1.
No authorized personnel is required for the installation and commissioning of the Touch Line video door system
s
for
1-5 Families (DIY)!
2.
The supply and command central units will be installed inside the building. They can be mounted on a DIN rail (
46277-3,
EN50022, IEC60715
) or directly on the wall and they will be connected to the
110/230Va.c. - 50/60Hz
network through
a grounded socket.
3.
For mounting, operation and service/ maintenance,
it is mandatory to comply with the SAFETY INSTRUCTIONS
presented in
Ch. 1
of this user manual
.
+14V
C/D
6mm
25-30mm
GND
Vout
Recommended cables for the Touch Line video door systems
3
EN
3
Recommended installation cables
:
2
4 wires x 0.5 mm
(type
H03VV-F4G 0.5
)
for max
.
60 ml
2
4 wires x 0.75 mm
(type
H05VV-F4G 0.75
) for
max
.
1
0
0 ml
Significance of the connections:
+14V
: the (+) connection for power supplying the system components (= 12 14V)
C/D
: the connection for audio communication (analog) and digital data transmission (CAN)
GND
: the (-) connection for power supplying the system components (GND = 0V)
Vin/Vout
: the connection for video signals transmission - PAL/SECAM analog 1Vpp
Example: +14V
= red,
C/D
= blue,
GND
= black,
Vin/Vout
= green.
Maintain the same colors for the same connections
throughout the system.
UTP/FTP cat5e (AWG24) or UTP/FTP cat6 (AWG23)
for max.
150 ml
+
14
C/D
GND
20-25mm
6mm
Vin
+
14
C/D
GND
20-25mm
6mm
Vout
Summary of Contents for Touch Line SCU.VDR03.BLG14
Page 19: ......