When working with products which are in contact to dangerous electrical voltages, attention must 
be payed to the relevant valid VDE / IEC / EN regulations. Especialy with refrence to the following 
rules:

VDE 0100, VDE 0550 / 0551, VDE 0711, VDE 0860, IEC 664, IEC 742, IEC 570, IEC 65

In case of non-observance of this instructions, the unit or other equipment might be damaged 
and no warranty or liability could be accepted.

When it is necessary to use tools with the units, components parts or subassemblies make it
sure, that the power is disconnected from the units and all electric charge which is stored in
components inside the unit are discharged.

Before opening the equipment disconnect the power cord or make sure, that the power is off
and the unit is currentless. It is only allowed to set components parts, subassemblies or units
into operation, if they are mounted in a shockproof housing. During the installation the unit
has to be currentless and the power has to be off.

Lifeparts (power cords and leads) which are connected to the units, components or
subassemblies have to be inspected for damage insulation or breaking. If a failure at the
power cord is detected the unit or the subassembly has to be put out of service at once. It is not
allowed to reopen the unit or the subassembly before replacing the damaged power cord.

It is the user’s responsibility to see that the marginal values of the equipment are not exeeded.

If it is not to distinguished for the not industrial ultimate user by the presented operating
instruction, which electrical data are the correct for the unit or the subassembly, a technical
adviser has always to be asked for technical information.

The observance of construction requirements and safety rules (VDE, IEC, employers liability 
insurenance i.e.) is subject to the user/customer.

Beim Umgang mit Produkten, die mit elektrischen Spannungen in Berührung kommen, müssen die 
gültigen VDE / IEC / EN Vorschriften beachtet werden. Besonders sei auf folgende Vorschriften 
hingewiesen:

VDE 0100, VDE 0550 / 0551, VDE 0711, VDE 0860, IEC 664, IEC 742, IEC 570, IEC 65

Bei Nichtbeachtung der Bedienungsanleitung oder der Anschlußvorschrift, z.B. bei 
Vertauschen der Anschlußklemmen, kann das Gerät oder die Anlage beschädigt werden und
der Betreiber verliert seinen möglichen Haftungsanspruch.

Werkzeuge dürfen an Geräten, Bauteilen oder Baugruppen nur benutzt werden, wenn 
s i c h e r g e s t e l l t   i s t ,   d a ß   d i e   G e r ä t e   v o n   d e r   Ve r s o r g u n g s s pa n n u n g   g e t r e n n t
sind und elektrische Ladungen die in im Gerät befindlichen Bauteile gespeichert
sind, vorher entladen wurden.

Vor dem Öffnen des Gerätes den Netzstecker ziehen oder sicherstellen, daß das Gerät
stromlos ist. Bauteile, Baugruppen oder Geräte dürfen nur in Betrieb genommen werden,
wenn sie vorher in ein berührungssicheres Gehäuse eingebaut wurden. Während des 
Einbaus müssen sie stromlos sein.

Spannungsführende Kabel oder Leitungen mit denen das Gerät, das Bauteil oder die
Baugruppe verbunden sind müssen stets auf Isolationsfehler oder Bruchstellen untersucht
werden. Bei Feststellen eines Fehlers in der Zuleitung muß das Gerät unverzüglich aus dem
Verkehr genommen werden, bis die defekte Leitung ausgewechselt worden ist.

Der Anwender hat dafür Sorge zu tragen, daß die angegebenen Gerätedaten nicht
überschritten werden.

Wenn aus den vorgelegten Beschreibungen für den Anwender oder Erwerber nicht eindeutig
hervorgeht, welche Kennwerte für ein Gerät oder Bauteil gelten, so muß stets ein Fachmann
 um Auskunft ersucht werden.

Im übrigen unterliegt die Einhaltung von Bau- und Sicherheitsvorschriften aller Art ( VDE, TÜV,
Berufsgenossenschaften ) dem Anwender / Käufer.

Allgemeine Sicherheitsvorschriften :

General safety rules :

- konform

Betriebsanleitung

Bitte sorgfältig beachten!

Operating instructions

Please observe carefully!

PSU90 / 100

PSU140 / 160

Anschlußschema 115V/230V  / Cable arrangement 115V/230V

Laststromdiagramm / Load-current diagram

0

0

10

2

4

6

8

5

10

15

20

25

30

yp 4V

T

2

24V

12V

Ty 12

p V

Volt DC

Amp.

Ausgangsstrom / Output current

A

u

s

g

a

n

g

s

s

p

a

n

n

u

n

g

 /

 O

u

tp

u

v

o

lt

a

g

e

Eingangsspannungstoleranz

Frequenz

Verbrauch  

 

      PSU90 / 100 / 140 / 160

Eingangsstrom  PSU90 / 100 / 140 / 160

Ausgangsgrößen

Ausgangsspannungen U

NENN

Ausgangsstrom I

NENN

Restwelligkeit

Betriebsdaten

Einschaltdauer (ED)

Arbeitstemperatur

Temperaturkoeffizient

Lagertemperaturbereich

Wirkungsgrad

Kühlung

Schutzeinrichtungen

Vorsicherung   PSU90 / 100 / 140 / 160

Ausgangssicherung

Überlastschutz

Netzausfallüberbrückung

MTBF

Sicherheitsdaten

Prüfspannung Trafo

Hochspannungsfestigkeit

Luft- und Kriechstrecken

Funkenentstörgrad

Anwendungsklasse

Umgebungsfeuchte

Schutzart Gehäuse

Schutzart Klemmen

Rüttelfestigkeit

Angewandte Bauvorschriften

gemäß VDE

IEC

EN

CSA / UL

Mechanik

Befestigung

Maße PSU90

PSU100

 PSU140
 PSU160

Maße 
Maße
Maße

Gewicht PSU90 / 100 / 140 / 160

Eingangsspannung 

siehe Gehäuseaufdruck des Gerätes

+15% und -15%

45 - 66 Hz

max. 65VA / 105 VA / 140VA / 175VA

max. 0,3A / 0,5A / 0,65A / 0,8A

siehe Gehäuseaufdruck des Gerätes

siehe Gehäuseaufdruck des Gerätes

< 3%

100%

-40°C bis +70°C

< 500ppm / K

-40°C...+105°C

ca. 87%

natürliche Konvektion (S)

5,0Amp. träge

nicht erforderlich da kurzschlußfest

20 mSek. typ.

> 400.000 h

5 kVac gemäß VDE 0551

Eingang / Ausgang 3,75 kVac

nach VDE 0806 / IEC 380

Primärkreis - Sekundärkreis >8mm

nach VDE 0110

< K nach VDE 0871 und EN 55022/B

KSE nach DIN 40040

95% relative Feuchte im Jahresdurchschnitt

Betauung möglich - tropentauglich

IP 65

IP 20 (VGB4)

>30g bei 33Hz in X, Y und Z,

nach IEC 68 und DIN 41640

VDE 0100, 0110, 0113, 0551, 0160, 804-8

IEC 380, 742, 950

EN 60950, EN50081, EN50082

CSA 22.2 / UL1012

Auf Schiene nach DIN 46277

47mm x 99mm x 118mm BxHxT)
64mm x 99mm x 118mm (BxHxT)
79mm x 99mm x 118mm (BxHxT)
94mm x 99mm x 118mm (BxHxT)

ca. 1,3kg / 1,85kg / 2,35kg / 2,85kg

Input voltage

Consumption PSU100 / 140 / 160

Input current  PSU90 / 100 / 140 / 160

Output data

Output voltage U

NOMINAL

Output current I

NOMINAL

Residual ripple

Operating data

Duty circle

Operating temperature

Temperature coefficient

Efficiency

Cooling

Safety devices

Output fuse

Overload protection

Hold-up time

MTBF

Safety data

Test voltage transformer

High-voltage resistance

Air gaps and leakage paths

Degree of EMI suppression

Class of application

Ambient humidity

Protective class enclosure

Protective class terminals

Vibration proof

Applied construction regulations

according to VDE

IEC

EN

CSA / UL

Mechanics

Mounting

Dimensions PSU90

PSU100
PSU140
PSU160

Dimensions 
Dimensions 
Dimensions 

Weight PSU90 / 100 / 140 / 160

Eingangsgrößen

Input data

Input voltage tolerance

Frequency

Storage temperature range

Fuse for input  PSU90 / 100 / 140 / 160

Technische Daten

Technical Data

im Gerät integriert

Die Geräte sind für sinusförmige Eingangsspannungen ausgelegt.

Ausgang Potentialfrei nach VDE 0551

Technische Daten siehe Tabelle rechts.

see face plate

+15% and -15%

45 - 66Hz

max. 65VA / 105 VA / 140VA / 175VA

max. 0,3A / 0,5A / 0,65A / 0,8A

EN 60950, EN50081, EN50082

see face plate

see face plate

< 3%

100%

-40°C to +70°C

< 500 ppm / K

-40°C...+105°C

ca. 87%

selfcooling (S)

5,0 Amp. delayed

not necessary - cont. short-circuit proof

20 msec. typical

> 400.000 h

5 kVac in accordance to VDE 0551

Primary circuit - secondary circuit 3,75 kVac

acc. to VDE 0806 / IEC 380

Primary circuit - secondary circuit >8mm

acc. to VDE 0110

< K in acc. to VDE 0871 and EN 55022/B

KSE according to DIN 40040

95% rel. humidity, yearly average dewing

allowed for use in tropical ambient

IP 65

IP 20 (VGB4)

>30g at 33Hz in X, Y and Z,

acc. to IEC 68 and DIN 41640

VDE 0100, 0110, 0113, 0551, 0160, 804-8

IEC 380, 742, 950

CSA 22.2 / UL1012

on rails acc. to DIN 46277

47mm x 99mm x 118mm (W x H x D)
64mm x 99mm x 118mm (W x H x D)
79mm x 99mm x 118mm (W x H x D)
94mm x 99mm x 118mm (W x H x D)

ca. 1,3kg / 1,85kg / 2,35kg / 2,85kg

integrated into device

Die Geräte vom Typ PSU100 / 140 / 160 sind anschlußfertige,
ungeregelte Netzgeräte.

Tropentauglich - Gießharzvollverguß

Die grüne LED signalisiert den Betrieb des Gerätes.

Kurzschlußfest, leerlauf- und überlastsicher

Die Geräte eignen sich zur Montage auf 35mm Hutprofil-
schienen 

. Befestigungsalternativen siehe

R ckseite dieser Bedienungsanleitung.

gemäß DIN 46277

ü

The power supplies are suitable to be fitted on 35mm rail

. Mounting alternatives are shown on backpage.

acc. to DIN 46277

The correct operation of the unit is indicated by the green LED.

Short- circuit proof, no-load and overload safe

Suitable for the tropics - Epoxy resin casted

Output separated according to VDE 0551

The units are constructed for sinus-oidal input voltage.

The power supply units of the series PSU100 / 140 / 160 are
ready for installation on delivery.

Technical data see table on the right side.

Vorsicherung

   PS1U90 / 100 / 140 / 160

Vorsicherung

   PS2U100 / 140 / 160

8,0 Amp. träge

2,0 Amp. träge

Fuse for input 

 PS1U90 / 100 / 140 / 160

Fuse for input

  PS2U100 / 140 / 160

8,0 Amp. delayed

2,0 Amp. delayed

GmbH

Postfach 1521
D - 22905 AHRENSBURG

Telefon: 04102 - 42082
Telefax: 04102 - 40930
                www.feas.de

© 2004

®

Eingangsstrom

  PS1U90 / 100 / 140 / 160

Eingangsstrom

  PS2U100 / 140 / 160

max. 0,6A / 1,0A / 1,25A / 1,6A

max. 0,3A / 0,4A / 0,5A

Input current

  PS1U90 / 100 / 140 / 160

Input current

  PS2U100 / 140 / 160

max. 0,6A / 1,0A / 1,25A / 1,6A

max. 0,3A / 0,4A / 0,5A

PS2U100

Netzspannung

line-voltage

PS2U100 - 400 V~

+

-

Verbraucher

consumer

L1

PE

L2

PSU100  /  PS1U100

+

-

Verbraucher

consumer

Netzspannung

line-voltage

PSU100   - 230 V~
PS1U100 - 115 V~

L1

PE

N

PSU140  /  PS1U140

+

-

Verbraucher

consumer

Netzspannung

line-voltage

PSU140   - 230 V~
PS1U140 - 115 V~

L1

PE

N

PS2U140

+

-

Verbraucher

consumer

Netzspannung

line-voltage

PS2U140 - 400 V~

L1

PE

L2

PSU160  /  PS1U160

PS2U160

Netzspannung

line-voltage

PS2U160 - 400 V~

+

-

Verbraucher

consumer

L1

PE

L2

0

0

6

12

5

10

15

20

25

30

Typ 24V

24V

12V

y

T p 12V

 

PSU160

Volt DC

Amp.

Ausgangsstrom / Output current

A

u

s

g

a

n

g

s

s

p

a

n

n

u

n

g

 /

 O

u

tp

u

v

o

lt

a

g

e

bei nominaler Eingangsspannung

at nominal input voltage

3

9

PSU100

bei nominaler Eingangsspannung

at nominal input voltage

15

Anschlußschema 400V  / Cable arrangement 400V

+

-

Verbraucher

consumer

L1

PE

N

PSU90 / PS1U90

Netzspannung

line-voltage

PSU90   - 230 V~
PS1U90 - 115 V~