2.1.
“20-01” OG300 Solar Water Heater Specifications
COLLECTOR (Panel)
Trim & Frame Materials:
Finished 27 mil Aluminum Trim and Frame = Total 54 mil (1.37 mm).
Absorber Material:
“Black Crystal” coated - all Copper with unions.
Glazing:
.236” (6.0 mm) Twinwall Polycarbonate UV Treated
Dimension / Weight:
200 -144.3”x 20.”x 3” 38 lb
(3.67 m x 0.51 m x 0.076 m 17.24 Kg)
18.4 Net s/f (1.71 m
2
)
Fluid Capacity:
.3/10 gallon
Recommended Flow Rates:
.20 to .35 GPM (0.946 to 1.324 L/min)
Maximum Working Pressure:
150 PSI (10.21 atm).
Maximum Stagnation Temp:
250
°
F (121.11
°
C).
Heat Transfer Fluid:
Potable water or Propylene glycol
Standard Components:
Mounting rails, mounting brackets, tech screws and lags
Color:
Musket Brown (Cl01 – default color) or Dove/Old Town Gray (C109) + optional colors
PV (Photovoltaic) POWERED CIRCULATOR
PV Panel:
20 or 30 Watt, 12volt DC
Circulator:
12 Volt - “El Sid”, March or equal.
FREEZE PROTECTION
Type:
Closed Loop Glycol with Storage Tank Heat Exchanger.
The SolarRoofs.com's closed loop Propylene Glycol Antifreeze heat exchange system's collector as well as feed and return
lines will not be damaged by (ambient) hard freeze temperatures as low as -54 degrees F below zero with a 60/40 mixture of
propylene glycol/water. The solar storage tank must be kept in an area above 32 degrees F.
CONNECTING LINES, INSULATION (standard)
Tubing:
1/2” (12.7 mm) OD copper - 50’ (15.24 m)
Insulation (6’ (1.83 m) supplied): 1/2” (12.7 mm) ID 1/2” (12.7 mm) or 3/4” (19.05 mm) wall
TUBING CONNECTION METHODS (standard)
Type:
Brass Union, Compression, (Brass Fittings for Heat Exchanger)
STORAGE TANK - Rheem / Rudd / Richmond Model Number: 81V080HE1 (Not Supplied)
80 Gallon Tank with In Tank Double Wall Heat Exchanger.
Fluid Used:
Propylene Glycol (Sierra)
Components Supplied:
Expansion Tank, one floating ball check valve, Temperature Gauge,
fill, drain, and pressure relief valves.
CONTROL
Type:
12 Volt Circulator with Switch, which automatically regulates circulator operation.
Although we will make every effort to give notice, Specifications and prices subject to change without notice.
2.1.1.
Antifreeze Safety Data - Sierra Antifreeze-Coolant
FLUID HANDLING, SAFETY AND FIRST AID:
1. Store fluid in tightly closed and properly vented containers, away from heat, sparks or open flame.
Dispose of any aqueous waste at permitted landfill sites only.
2. Chemical splash goggles or full face shield must be worn when possible eye contact exists.
3. Ingestion: Give pint of luke warm water or induce vomiting if large quantity is ingested.
4. EMERGENCY PHONE: 1-800-424-9300 (CHEMTREC)
Freezing point: -28 deg F (50/50 mixture)
Flash Point: 211F
Boiling point: 365 deg F
Appearance: Green
Specific Gravity: 1.04
Vapor Density: 2.6