The Alpha H2 heater should only be wall mounted in a
horizontal manner or hung from a ceiling from chains
(not supplied).
•
When wall mounting the Alpha H2 heater in a
horizontal manner, do not position the heater at an
angle more than 50° and less than 30° as shown in
Fig. A.
•
When ceiling hanging the Alpha H2 heater, ensure the
minimum distance from the ceiling is adhered to as
shown in Fig. B.
Continued on next page...
I N S TA L L AT I O N
The 208 / 240V version of the heater is fitted with 2 × supply cords measuring 79 inches
(200 cm) for hard wiring.
WARNING:
Wiring procedures and connections should be in accordance with the
National Electric Code (NEC) and local codes.
WARNING:
If the supply cord(s) becomes damaged, it must be immediately replaced by a
qualified person in order to avoid a hazard.
CAUTION:
Disconnect electric power supply before working on circuit wiring to prevent
electric shock.
CAUTION:
Please observe the minimum safe distance between the heater body and any
inflammable surfaces.
CAUTION:
When the electrical connection is outside weatherproof sockets must be used
having ground fault protection (GFCI or GFI).
NOTE: CONSULT A QUALIFIED ELECTRICIAN, IF IN DOUBT.
!
C O N F I G U R AT I O N S
The Alpha H2 heater is a double emitter - it contains two emitters. It can be installed as a
single unit or joined to one or two more single units. Joining bars are available that connect
the heaters together to increase the size and output of the installation. The maximum
number of units that can be joined together is three. Please read the section ‘joining heaters
together’ for information on how this should be done.
M O U N T I N G - 1 × D O U B L E ( T W O E M I T T E R S ) U N I T
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
Switch off/unplug the heater from the mains supply
when mounting or adjusting the heater position.