background image

 

SOLAHART PV SYSTEM WARRANTY - AUSTRALIA ONLY 

17 

PART F - LABOUR WARRANTY 
Warranty coverage for labour 

– PV System 

In addition to the above coverage, Solahart provides you with 5 years of coverage, from the date of installation, 
for  all  labour  costs  involved  with  inspection  by  Solahart,  removal  or  installation  of  warranted  parts  or 
components by Solahart of your PV System. Other than this 5 years coverage, this Warranty does not cover, 
nor  will  Solahart  reimburse, any  on-site  labor  or  other  costs  incurred  in  connection  with the  inspection,  de-
installation or removal of defective parts or components, or the re-installation of replaced or repaired parts or 
components for your PV System. 
 

Warranty coverage for labour - SolarEdge Products 

If Solahart determines that a reported defect in relation to a SolarEdge Product is eligible for coverage under 
this Limited Warranty and Solahart decides to repair the Product or part(s), warranty coverage includes labour 
and material costs necessarily incurred to correct the Product defect; and where Solahart decides to replace 
the  Product  or  part(s)  to  which  the  Limited  Warranty  applies,  warranty  coverage  includes  the  cost  of  the 
replacement of the Product or part(s). All other costs will be borne by you. 
 

PART G - GENERAL TERMS 
Back-up if sole or dominant power supply 

If the PV System is to be the sole or dominant power supply for your business or application, you should ensure 
that you have back up redundancy if the PV System were to become inoperable for any reason. We suggest 
that  you  seek  advice  from  your  electrician  or  qualified  professional  about  your  needs  and  build  backup 
redundancy into your electricity supply system. 
 

Application of this warranty 

This warranty requires the  Products to be installed according to the  latest safety, installation  and operation 
instructions provided by Solahart and with all relevant statutory and local requirements in the State or Territory 
in  which  the  Products  are  installed,  and  does  not  apply  to  defects,  damage,  malfunction,  power  output  or 
service failures which have been caused by: 

1. 

Storage, installation, commissioning, repair, modifications, alterations, attachments or movement to or of 
the Product or otherwise without the prior written consent of Solahart; 

2. 

Abuse, misuse or abnormal use, accident, negligent acts, power failures or surges, force majeure events 
including but not limited to lightning, fire, flood, hail, extreme cold weather, or any other natural disaster, 
any other force majeure event, pest damage, accidental breakage, actions of third parties, and any other 
events or accidents o

utside Solahart’s control and/or not arising under normal operating conditions;  

3. 

Operating the Product in an unintended environment or under incorrect safety or protection conditions;  

4. 

Failure to install, operate and/or maintain the Product in accordance with the applicable Solahart 

Owner’s 

Guide and Installation Instructions; 

5. 

Transport damage; 

6. 

Wear and tear from adverse conditions including corrosive atmospheric conditions e.g. salt, ocean spray, 
dust storm or other weather damage; 

7. 

Cosmetic defects;  

8. 

Any improper attachment, installation or application of the Product, and in respect of the PV System, any 
insufficient framing if the PV System is a frameless module;  

9. 

Any  attempt  to  extend  or  reduce  the  life  of  the  Product,  whether  by  physical  means,  programming  or 
otherwise, without the prior written consent of Solahart; 

10. 

Removal and reinstallation at a location other than the original installation location, without the prior written 
consent of Solahart; 

11. 

Insufficient ventilation of the Product;  

12. 

Failure  to  observe  the  applicable  safety  regulations;  or  any  factor  identified  in  the  applicable  Solahart 
Owner’s Guide and Installation Instructions; or 

13. 

Ignoring safety warnings and instructions contained in all documents relevant to the applicable Product. 

Summary of Contents for PV Series

Page 1: ...Solahart PV Systems must be installed and serviced by a suitably qualified person Please leave this guide with the PV system owner Owner s Guide PV Systems ...

Page 2: ...ated and maintained in accordance with these instructions the system installation instructions and the installation guide supplied with the PV inverter Caution Only qualified and accredited personnel should perform work on PV systems such as design installation commissioning maintenance and repairs Only Solahart parts and Solahart approved parts may be used No substitute parts may be used without ...

Page 3: ...3 CONTENTS Contents 3 About Your PV System 4 Electrical Safety 6 Operating Procedures 7 Periodic Maintenance 8 Engineering Certification 10 Solahart PV System Warranty Australia Only 14 ...

Page 4: ...grid the direct current is transformed into alternating current AC by the inverter This conversion is also known as DC to AC inversion The alternating current generated by the inverter is fed into the main switchboard which in turn is connected to the grid Note For safety reasons unless your system is specifically designed to power a backup circuit the inverter will only operate when the mains ele...

Page 5: ...nected in series An array is composed of one or more strings connected in parallel The inverter converts direct current produced by the array into alternating current The PV Array D C Isolators provide a means for isolating the array The Inverter A C Isolator provides a method of isolating the PV System from the electrical distribution grid It may also protect the inverter from excess AC current ...

Page 6: ...nguishing They are a potentially lethal burn and fire hazard capable of creating high temperatures that can destroy contacts and connectors EARTH FAULTS Normally the DC circuitry of the PV system is insulated from earth An earth fault is a system fault where a short circuit is formed between the DC circuitry of the PV system and earth As the PV system owner please be aware of the current method of...

Page 7: ...urn OFF Main Switch Inverter Supply at AC Switchboard and Inverter A C Isolator at Inverter where Installed 2 Turn OFF Backup A C Main Switch where Installed 3 Turn OFF PV Array D C Isolator s and Battery D C Isolator where Installed Warning Depending upon the system there may be more than one PV Array D C Isolator Warning To effectively isolate the wiring between the AC isolator and switchboard t...

Page 8: ... that your system is operating data has been logged and communication has been maintained Ensure that the contact details of the PV system owner or responsible officer are up to date to ensure that inverter fault notifications are delivered Monthly If you are unable to log in or your system is not operating correctly contact your Solahart dealer Visual inspection of PV system components from groun...

Page 9: ...de display screens LED indications are explained in the table below LED Status Explanation Green Flashing 2 seconds on 2 seconds off Waiting for connection conditions Glowing Operating normally Red Glowing Error Contact your Solahart Dealer Blue Flashing slowly for 1 minute Communication connection is being established Glowing Communication active ...

Page 10: ...10 ENGINEERING CERTIFICATION ...

Page 11: ...ENGINEERING CERTIFICATION 11 ...

Page 12: ...ENGINEERING CERTIFICATION 12 ...

Page 13: ...ENGINEERING CERTIFICATION 13 ...

Page 14: ...he subsequent version Solahart issues the following voluntary warranty to 1 The end user who purchased the System in Australia and put the System into use for the first time the Original End User and 2 In the case of SolarEdge Products only any owner of the Product subsequent to the Original End User who provides proof of title transfer provided that the Product has never been relocated from its o...

Page 15: ...e output of your Module Solahart does not warrant a specific power output for your Modules All modules degrade over time and power output is subject to many variables including the age of the Module PART B INVERTERS SMA AND ABB Warranty coverage for SMA and ABB Inverters Solahart warrants that the Inverter when located at its original installation will operate in accordance with its specifications...

Page 16: ...oducts from Solahart for use in accordance with their intended purpose Original Buyer The Limited Warranty may be transferred from the Original Buyer to any assignee and will remain in effect for the time period remaining under the above Warranty Periods provided that the Products are not moved outside their original country of installation and any reinstallation is done in accordance with the ins...

Page 17: ...ovided by Solahart and with all relevant statutory and local requirements in the State or Territory in which the Products are installed and does not apply to defects damage malfunction power output or service failures which have been caused by 1 Storage installation commissioning repair modifications alterations attachments or movement to or of the Product or otherwise without the prior written co...

Page 18: ...o the repaired or replaced Product and the repaired or replaced Product or parts will not carry a new Solahart Warranty The Warranty Periods set out above will not be extended in any way in the event of a replacement or repair of a Product but this does not affect any rights you may have under the Australian Consumer Law in relation to the replaced or repaired Product see the section below entitle...

Page 19: ... on site or whether the Product must be sent elsewhere for testing and assessment 3 If Solahart determines in its sole discretion that you have a valid warranty claim Solahart will organise for the repair or replacement of the Product or any component in accordance with this warranty Any expenses incurred in the making of a claim under this Warranty will be borne by you Before any SolarEdge Produc...

Page 20: ... Alan Street PO Box 7508 Silverwater 2128 Rydalmere New South Wales 2116 Australia For SERVICE Telephone 1800 638 011 or your nearest Solahart Dealer For Sales Telephone 1300 769 475 or your nearest Solahart Dealer www solahart com au Revision Date 2017 October 122232E ...

Reviews: