SOLAHART PV SYSTEM WARRANTY - AUSTRALIA ONLY 

16 

Warranty coverage for Power Optimizers 

Subject to the terms and conditions of this Limited Warranty, Solahart provides a warranty against defects in 
workmanship and materials in relation to the Power Optimizers for a period of ten (10) years commencing on 
the earlier of: 

1. 

4 months from the date the Power Optimizers are shipped from the manufacturer; and 

2. 

The date of installation of the Power Optimizers. 

For all Power Optimizers with a part number ending in C, this warranty does not apply to the input connector.  

Warranty coverage for Power Meter 

Subject to the terms and conditions of this Limited Warranty, Solahart provides a warranty against defects in 
workmanship and materials in relation to the Power Meter for a period of five (5) years commencing on the 
earlier of: 

1. 

4 months from the date the Power Meter is shipped from the manufacturer; and 

2. 

The date of installation of the Power Meter. 

Remedies 

If Solahart determines that a reported defect in relation to a Product is eligible for coverage under this Limited 
Warranty (including retention capacity), Solahart will, at its sole option: 

1. 

Repair the defective Product; 

2. 

Issue a credit note for the defective Product in an amount up to its actual value at the time buyer notifies 
Solahart of the defect, as determined by Solahart, for use toward the purchase of a new Product; or 

3. 

Provide the buyer with replacement units for the Product. 

Exclusions 

The  Limited  Warranty  does  not  apply  to  components  which  are  separate  from  the  Products,  ancillary 
equipment and consumables, such as, for example, cables, fuses, wires and connectors. 
 

Beneficiary of Limited Warranty 

The  Limited  Warranty  only  applies  to  the  buyer  who  purchased  the  Products  from  Solahart,  for  use  in 
accordance with their intended purpose (‘Original Buyer’). The Limited Warranty may be transferred from the 
Original  Buyer  to  any  assignee,  and  will  remain  in  effect  for  the  time  period  remaining  under  the  above 
Warranty Periods, provided that the Products are not moved outside their original country of installation and 
any reinstallation is done in accordance with the installation directions and use guidelines accompanying the 
Products.  
 

PART D 

– THE RACKING SYSTEM 

Warranty coverage for the Racking System 

Solahart warrants that the racking system supplied with the PV System shall be free from defects in material 
and workmanship for a period of five (5) years from the date of installation. 
 
This Warranty shall be void if installation of the racking system is not performed in accordance with the 

Owner’s 

Guide  and  Installation  Instructions,  or  if  the  racking  system  has  been  modified,  repaired,  or  reworked  in  a 
manner  not  previously  authorized  by  Solahart  in  writing.  If  within  the  specified  Warranty  period  the  racking 
system  shall  be  reasonably  proven  to  be  defective,  then  Solahart  shall  repair  or  replace  the  defective 
component(s) at Solahart’s sole discretion. Such repair or replacement shall completely satisfy and discharge 
all of Solahart’s liability with respect to this Limited Warranty. 
 

PART E - BALANCE OF THE SYSTEM 
Warranty coverage for the balance of the system 

The balance of the PV System (

BOS

) consists of PV module cabling, circuit breakers, isolators, enclosures 

and labels. Solahart warrants that the BOS supplied by it will operate in accordance with its specifications in 
the Owner’s Guide and Installation Instructions for a period of five (5) years from the date of installation of the 
BOS. If the BOS fails to operate in accordance with its specifications and this materially affects the usability of 
the BOS, Solahart will, at its sole option, repair or replace the defective component. 
 

 

Summary of Contents for PV Series

Page 1: ...Solahart PV Systems must be installed and serviced by a suitably qualified person Please leave this guide with the PV system owner Owner s Guide PV Systems ...

Page 2: ...ated and maintained in accordance with these instructions the system installation instructions and the installation guide supplied with the PV inverter Caution Only qualified and accredited personnel should perform work on PV systems such as design installation commissioning maintenance and repairs Only Solahart parts and Solahart approved parts may be used No substitute parts may be used without ...

Page 3: ...3 CONTENTS Contents 3 About Your PV System 4 Electrical Safety 6 Operating Procedures 7 Periodic Maintenance 8 Engineering Certification 10 Solahart PV System Warranty Australia Only 14 ...

Page 4: ...grid the direct current is transformed into alternating current AC by the inverter This conversion is also known as DC to AC inversion The alternating current generated by the inverter is fed into the main switchboard which in turn is connected to the grid Note For safety reasons unless your system is specifically designed to power a backup circuit the inverter will only operate when the mains ele...

Page 5: ...nected in series An array is composed of one or more strings connected in parallel The inverter converts direct current produced by the array into alternating current The PV Array D C Isolators provide a means for isolating the array The Inverter A C Isolator provides a method of isolating the PV System from the electrical distribution grid It may also protect the inverter from excess AC current ...

Page 6: ...nguishing They are a potentially lethal burn and fire hazard capable of creating high temperatures that can destroy contacts and connectors EARTH FAULTS Normally the DC circuitry of the PV system is insulated from earth An earth fault is a system fault where a short circuit is formed between the DC circuitry of the PV system and earth As the PV system owner please be aware of the current method of...

Page 7: ...urn OFF Main Switch Inverter Supply at AC Switchboard and Inverter A C Isolator at Inverter where Installed 2 Turn OFF Backup A C Main Switch where Installed 3 Turn OFF PV Array D C Isolator s and Battery D C Isolator where Installed Warning Depending upon the system there may be more than one PV Array D C Isolator Warning To effectively isolate the wiring between the AC isolator and switchboard t...

Page 8: ... that your system is operating data has been logged and communication has been maintained Ensure that the contact details of the PV system owner or responsible officer are up to date to ensure that inverter fault notifications are delivered Monthly If you are unable to log in or your system is not operating correctly contact your Solahart dealer Visual inspection of PV system components from groun...

Page 9: ...de display screens LED indications are explained in the table below LED Status Explanation Green Flashing 2 seconds on 2 seconds off Waiting for connection conditions Glowing Operating normally Red Glowing Error Contact your Solahart Dealer Blue Flashing slowly for 1 minute Communication connection is being established Glowing Communication active ...

Page 10: ...10 ENGINEERING CERTIFICATION ...

Page 11: ...ENGINEERING CERTIFICATION 11 ...

Page 12: ...ENGINEERING CERTIFICATION 12 ...

Page 13: ...ENGINEERING CERTIFICATION 13 ...

Page 14: ...he subsequent version Solahart issues the following voluntary warranty to 1 The end user who purchased the System in Australia and put the System into use for the first time the Original End User and 2 In the case of SolarEdge Products only any owner of the Product subsequent to the Original End User who provides proof of title transfer provided that the Product has never been relocated from its o...

Page 15: ...e output of your Module Solahart does not warrant a specific power output for your Modules All modules degrade over time and power output is subject to many variables including the age of the Module PART B INVERTERS SMA AND ABB Warranty coverage for SMA and ABB Inverters Solahart warrants that the Inverter when located at its original installation will operate in accordance with its specifications...

Page 16: ...oducts from Solahart for use in accordance with their intended purpose Original Buyer The Limited Warranty may be transferred from the Original Buyer to any assignee and will remain in effect for the time period remaining under the above Warranty Periods provided that the Products are not moved outside their original country of installation and any reinstallation is done in accordance with the ins...

Page 17: ...ovided by Solahart and with all relevant statutory and local requirements in the State or Territory in which the Products are installed and does not apply to defects damage malfunction power output or service failures which have been caused by 1 Storage installation commissioning repair modifications alterations attachments or movement to or of the Product or otherwise without the prior written co...

Page 18: ...o the repaired or replaced Product and the repaired or replaced Product or parts will not carry a new Solahart Warranty The Warranty Periods set out above will not be extended in any way in the event of a replacement or repair of a Product but this does not affect any rights you may have under the Australian Consumer Law in relation to the replaced or repaired Product see the section below entitle...

Page 19: ... on site or whether the Product must be sent elsewhere for testing and assessment 3 If Solahart determines in its sole discretion that you have a valid warranty claim Solahart will organise for the repair or replacement of the Product or any component in accordance with this warranty Any expenses incurred in the making of a claim under this Warranty will be borne by you Before any SolarEdge Produc...

Page 20: ... Alan Street PO Box 7508 Silverwater 2128 Rydalmere New South Wales 2116 Australia For SERVICE Telephone 1800 638 011 or your nearest Solahart Dealer For Sales Telephone 1300 769 475 or your nearest Solahart Dealer www solahart com au Revision Date 2017 October 122232E ...

Reviews: