INSTALLATION - RACKING
32
TILT LEG INSTALLATION
Note:
Screws supplied with the tilt legs are wood screws suitable for timber only. Screws used in metal
purlins must be suitable for metal structures and have a TPI (threads per inch) of 14.
1. Determine and mark position of feet according
to your plans. Pre drill through roof cladding
(on top of crest) at planned locations. Place
the supplied rubber gaskets under each foot
and ensure that a weatherproof seal is made
between the foot and the roof cladding.
2. Fix the foot to the timber batter or rafter using
a minimum of two M6 X 80 mm screws.
Ensure a minimum screw embedment of
35 mm for timber battens and 50 mm for
rafters.
If the interface is being fixed to metal purlins
use screws suitable for metal structures with a
TPI of 14.
Check the foot to ensure that the fastening
screws tightly fix the sealing gaskets without
damaging roof cladding.
Adjustable tilt leg foot
30º fixed tilt leg foot
3.
Adjustable tilt legs only:
Insert feet U
brackets into front feet and loosely fasten
Allen head bolt and nut to allow for later
adjustment. Allen head bolt and Z-module on
top of U bracket is utilised to attach rails in
next step.
4.
For adjustable tilt legs
: Place rear legs into
feet, insert Allen head bolt, washer, retaining
washer and nut and fasten loosely to allow for
later adjustment.
For 30º fixed tilt legs
: Place rear legs onto
feet, insert Allen head bolt, washer, retaining
washer and nut and tighten to 15-20 Nm.
Adjustable tilt legs
30º fixed tilt legs
5. Loosen the leg telescopic section Allen head
grub screws. Adjust the leg length according
to your plans and tighten the grub screws to
17 Nm.
6. Fix the leg L bracket to the leg using the Allen
head bolt, washer, retaining washer and nut
and fasten loosely to allow for later
adjustment.