43
SOUTH AFRICAN SYSTEM SANS 1307 DETAILS
System
181J
302J
Tank
180J / 180F
300J / 300F
Collector
1 x J
2 x J
Type
This is a dual purpose water heater.
For solar heating, this is an indirect heated tank.
Moisture Resistance Classification
IP34
IP34
Thermal Properties – Q factor
At 16 MJ/m
2
with temperature difference of 10°C.
19.04
35.535
Heat Loss Coefficient
2.93 W/K
2.04 W/K
Total Energy Rating – kW/h/m
2
/day
South African Climate
3.4
(J collector)
3.4
(J collector)
South African Tank Rated Capacity
175 litres
250 litres
South African Tank Rated Working Pressure
600 kPa (6 bar)
600 kPa (6 bar)
Standing Heat Loss / 24 hours – standard design
2.78 kWh
3.46 kWh
Standing Heat Loss / 24 hours – solar design
2.085 kWh
2.595 kWh
Rated Power Input
Either 1800, 2400, 3600, 4800 Watts – refer to tank rating label
Notes:
•
To ensure safe and effective performance, this water heater shall be installed, maintained and repaired strictly in
accordance with the appropriate and relevant requirements of SANS 10254.
•
For safe performance this water heater is fitted with a:
Thermostat
Non-self resetting thermal cut-out
Combination Temperature Pressure Relief (TPR) Valve (Safety Valve)
Pressure Control Valve and Expansion Control Valve (ECV) (unless the water supply pressure cannot exceed the
rated pressure of this water heater or its safety value whichever is lowest)
Heat exchange jacket (solar heater transfer fluid circuit) pressure relief valve (when operated with solar heating)
▪
80 kPa – without Over Temperature Protection (OTP) to the heat exchanger jacket vent port
▪
200 kPa – with Over Temperature Protection (OTP) to the heating fluid reservoir tank.
Warnings
This water heater MUST NOT BE OPERATED without each of these devices fitted and in working order.
The Temperature Pressure Relief Valve, Expansion Control Valve and their drain pipes must not be tampered with.
DO NOT seal or block the relief valve, control valve or drain pipe outlet.
Emergency Shut Down Procedure
If it is necessary to turn off the water heater:
•
Switch off the electrical supply at the isolating switch to the solar storage tank.
•
Close the cold water isolation valve at the inlet to the water heater.
•
Open a hot tap if it necessary to relieve the pressure in the water heater.
SOUTH AFRICAN SPECIFIC OPERATING COMPONENTS
SANS 198 Compliant
Pressure Control Valve
Caleffi 533CV4 – 400 kPa
Temperature Pressure Relief Valve (Safety Valve)
Apex – 400 kPa, 18 kW
Vacuum Breaker
Cobra PB 6.302
SANS 1808 Compliant
Drain Cock
not supplied