156
28. RECORDING DATA - TOPO MENU -
3. Set the following items.
(1) Target height
(2) Point name
(3) Code
4. Check the input data, then press
[REC]
.
5. Press {ESC} to quit measurement and restore <TOPO>.
Distance measurement data can be stored in the current JOB.
PROCEDURE
1. Press
[MEAS]
in the first page of OBS mode to perform
distance measurement.
"12.2 Distance and Angle Measurement"
2. Press
[TOPO]
in the third page of OBS mode. <TOPO> is
displayed.
Select “Dist data” to display the measurement results.
3. Set the following items.
(1) Target height
(2) Point name
(3) Code
4. Check the input data, then press
[REC]
.
28.4 Recording Distance Measurement Data
PT
HR
1 0 1 0
HA-R
H-SET
T I LT
R E C
0SET
CD
:
S R C H
L I S T
A D D
TOPO JOB1
Occupy
Angle data
Dist data
Coord data
BS data
OFFSET
REC
MEAS
AUTO
ZA
HA-R
HR
PT
SD
CD
:
A
H-SET
T I LT
R E C
0SET