background image

6

Troubleshooting

If during installation or operation anomaly or malfunctions are detected, the probable cause of the failure can be
found in the following manner:

1. No data come from the gateway; no data are available from the devices which communicate via the gateway

(hereinafter as

reading modules”). In this case try to find the cause of the failure as follows:

Find out whether there is an IP-connection between the gateway and the superior system by using of
the standard ”ping” test commonly used in the IP-network:

if the gateway is connected directly to the public network (it has a public IP-address), it should
respond to ”ping” test from any computer with an access to the public Internet;

if the gateway is connected to a private network (it has a private IP-address) and there is an access
to the edge router of the private network available, try to use ”ping” test from the edge router;

if the gateway is connected through a VPN/APN, ”ping” test can be performed from the computer
which has access to the VPN/APN.

Availability of the gateway and its functionality can be verified by using the WEB-application

Mod-

ules Online” (

Radar”) as described in paragraph

3.7

.

If the gateway is accessible and functional, try to find out the reason why the gateway does not receive
the signals from reading modules under the proceeding described in the paragraph 2;

If the gateway is not accessible examine its power supplying, especially:

whether there has been a power failure in the object,

whether the power supply is on,

whether the gateway is really under power supplying (the

Power” LED should be shining).

If the power supplying of the gateway is not working, repair wiring, power supply or A/C power input.

If the power supplying is correct and the gateway is not accessible, search for any circumstances which
may affect the IP-connectivity, especially if the local Internet access in the installation site is currently
available, if there are any changes in routing or in IP-addressing, or whether the

PIN-control of the

SIM is turned off

.

If the IP-connectivity is most likely available and the power supply is correct (LED

Power” on the

module shines), perform a quick check of connection to the local network according to the paragraph

5.9

.

In case that the gateway has no IP-address assigned, check functionality of the local IP network and reset
the module by disconnecting and connecting of the power supply (the source off/on). If this intervention
does not restore communication, replace the gateway according to the paragraph

5.7

If after replacing

the new module works correctly, label the dismantled module as ”defective”. If there is no apparent
physical damage on the module and it is still under warranty, follow the warranty claim procedure;

If the neither restart nor replacing of the module do not lead to restoration of the connection between
the gate and the superior system, solve the problem of IP-connectivity with experts in routing within
IP-network.

2. The module evidently communicates, answers to ”ping”, the result of the quick test of the gateway availability

is

OK”, but data does not come from all (or most) reading modules which communicate via the gateway. In

this case try to find the cause of trouble following way:

Check receiving functionality of the module in

Modules online” (

Radar”) mode as described in the

paragraph

5.9

If there is no device in the

Radar” table even after a long time, the module probably

does not receive any messages;

Ensure that there are no changes in the object, which could have the fatal effect on receiving quality;

Check the module visually for any damage of the antenna, antenna cable or connector. If there are any
doubts about functionality of any of these components, replace it;

Check the module settings according to the paragraph

3.4.6

(Commands of ”gw” subsystem for setting

of RF network communication), particularly settings of the communication mode and frequency channel
parameters;

If the module is configured correctly perform measuring of the signal strength from reading modules by
using of the analyzer (or other receiving device);

WB169-RFG

34

Summary of Contents for WB169-RFG

Page 1: ...WIRELESS COMMUNICATION SYSTEM Wireless M BUS WB169 RFG Revision 1 0 SOFTLINK s r o Tomkova 409 278 01 Kralupy nad Vltavou Czech Republic Phone 420 315707111 e mail sales softlink cz www softlink cz...

Page 2: ...nd cc subsystems for module initial setting and diagnostics 21 3 4 9 Command of ntp subsystem for setting of time synchronization 21 3 4 10 Command of hist subsystem for examination of History table r...

Page 3: ...and History menu items 24 7 Table of parameters of the WB169 RFG module that are readable via the optical interface 24 8 Telnet connection to the WB169 RFG module 25 9 Display of the History table of...

Page 4: ...correctness encodes repacks them into IP UDP frames and sends them to the configured IP address and a central application port number Wireless M Bus messages are packed to the IP UDP frames with usin...

Page 5: ...rity The module RF transceiver is equipped with the coaxial connector of SMA Female type designated for inter connection of an external antenna directly or via coaxial cable The GSM modem is equipped...

Page 6: ...GPRS EDGEB3 B8 Antenna characteristic impedance 50 Antenna connector SMA female Configuration interface USB Transmission speed 115 200 Baud Operation mode asynchronous Transmission rate 8 data bits 1...

Page 7: ...rameters and operational statistics of the module by using of optical converter can be found in the section 3 6 Setting of parameters by using of optical converter The description of checking and sett...

Page 8: ...rial port that the system automatically assigned to the virtual port at the moment of interconnection module to the computer The number of the serial port can be found in OS Windows by using of Device...

Page 9: ...rial line by pressing of ENTER key check the execution of the command by displaying of the list of configuration parameters which appears by entering show or and pressing on ENTER key to display a sum...

Page 10: ...terminal window GW33H7 0 show CPU info CPUID 411fc271 FPU Type 00000002 Flash size 2048 kB Flash bank size 1048576 B 0x00100000 Flash base addr 0x08000000 CPU UID 3339510a001c0036 SW version 1 02 dat...

Page 11: ...er s password cfgserver Config server IP cfgport Config server port usecfgserver Use config server 0 no 1 yes nepserver Default NEP server IP nepport Default NEP server port Utils loca location 0 63 c...

Page 12: ...lay 0 timeout 1671 172 16 16 1 status wait stratum 2 reach 3 delay 143 timeout 1681 The meaning of individual commands including subsystem commands is described below 3 4 3 Commands of System commands...

Page 13: ...xhhmmss format the date value is entered in the format of 0xYYMMDD The manually entered value is automatically corrected when the entries from external synchronization sources GSM or NTP are available...

Page 14: ...n be performed by using of userpass login oldpassword newpassword command GW33H7 0 userpass admin admin admin223 Password changed GW33H7 0 write Write config 0 GW33H7 0 By using of the nepserver and n...

Page 15: ...0 errors 0 Tx packets 0 bytes 0 errors 0 Interface eth0 status Down MAC 00 04 d0 ff ff ff Rx packets 0 bytes 0 errors 0 Tx packets 0 bytes 0 errors 0 Interface ppp0 status Up full duplex MTU 1500 IP A...

Page 16: ...or icmp connection test pin SIM pin useip IP on off usegps GPS on off usetime Sync time on off info show GSM info gps show GPS info cmux show CMUX info lcp show LCP info deb GSM debug write save curre...

Page 17: ...nication By using of gsm useip gsm usegps and gsm usetime commands with 0 1 parameter the individual services of gsm subsystem can be activated deactivated by gsm useip command the PPP connection to I...

Page 18: ...wer deb Set debug level write save current configuration cread read configuration show help By using of gw info command basic information about the setting of gw subsystem can be browsed This also inc...

Page 19: ...servers are displayed in the last lines of the gw info report including the time until the timeout expires In the third part of the file there are records of gateway traffic filters which can be used...

Page 20: ...are defined by the Wireless M Bus standard The setting can be performed by using of chan1 command followed by the required channel number Current setting can be displayed by using of the command witho...

Page 21: ...for checking and setting of the basic functions of module operating system as well as the basic communication functions of the module There are following commands Utils loca location 0 63 chars ekey S...

Page 22: ...s irrelevant for the WB169 RFG module The write cread and clear commands serve for management of saving data in the module memory The module contains two sets of configuration operating configuration...

Page 23: ...e monitor subsystem can be set This command is intended only for module checking and diagnostics By using of deb command without parameter setting of debug statements of all subsystems can be displaye...

Page 24: ...to check the current module configuration can be useful in normal operation 3 4 8 Commands of sys disp and cc subsystems for module initial setting and diagnostics The commands of these three subsyste...

Page 25: ...gateway receives more messages in a given interval the oldest messages are always deleted The History record table is used to monitor the gateway function its records can help to learn which terminal...

Page 26: ...bols that indicate the status of module main communication channels on top there is a standard image of signal strength symbolizing GSM communication with a graphical representation of GSM signal stre...

Page 27: ...e module using the optical converter are described in chapter 3 of the manual Configuration of wacoSystem product family devices available at download from the module manufacturer s website The list o...

Page 28: ...g application can be performed by entering the command ping and the IP address of the module from the command line of any computer Example of perform ing a ping availability check from the Windows Com...

Page 29: ...le is also equipped with a WEB server which enables display of some module parameters with using the HTTP protocol Currently it is possible to use WEB browser to display the content of the His tory ta...

Page 30: ...target application IP address The target application is the application that the gateway should send data The setting of target application IP address is dynamic using a mechanism of zero packets The...

Page 31: ...e is transported through the IP UDP uplink in following three NEP variables The first variable is Message type OID 63 It is a mandatory NEP protocol variable that indicates what type of message it is...

Page 32: ...cording to individual components of the M Bus address ID Manufacturer Version Medium If for example some specific Medium or Manufacturer codes are entered into the filter only messages with these code...

Page 33: ...the antenna connector of the device by tension or twist Excessive loads can damage or destroy antenna connectors The module is specified for installation in normal internal premises with the temperatu...

Page 34: ...d WB169 RFG module Installation of the module should be performed by the following procedure installation of the module can be performed only by a person with necessary qualification in electrical eng...

Page 35: ...g module turn the power supply off and disconnect the power supply cables from the module Disconnect the signal cable and the antenna cable from the module Release the module from DIN rail by pulling...

Page 36: ...ntentional shutdown malfunction of the Internet connection caused by a local failure of the GSM network or failure of the PPP connection caused by incorrect functioning of the authorization servers or...

Page 37: ...in routing or in IP addressing or whether the PIN control of the SIM is turned off If the IP connectivity is most likely available and the power supply is correct LED Power on the module shines perfo...

Page 38: ...test is positive but the data from some reading modules are not received In this case the problem may be caused by weakening of the signal in the area of the gateway antenna position failure of the ga...