SOFAR 15~24KTLX-G3
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd.
- 31 -
Figure 5-9 AC cable connection instruction diagram (1)
Step 3:
After assembling the PG waterproof connector, connect the cable to the AC
terminal block L1, L2, L3, N, PE contacts, and fasten them (4~5 N · m). Tighten the
lock nut of PG terminal clockwise (7~8 N · m).
Figure 5-10 AC cable connection instruction diagram (2)
5.4. Connect PV side of inverter (DC-Input)
DC Switch is a model of the following specifications or equivalent, subject to CEC
certification number.
Inverter model
Model of DC switch
SOFAR 15KTLX-G3
SOFAR 15KTLX-G3-A
SOFAR 17KTLX-G3
SOFAR 20KTLX-G3
SOFAR 20KTLX-G3-A
SOFAR 22KTLX-G3
SOFAR 24KTLX-G3
NDG3V-50/4/1/01/M/AS (
AZ 69025902
The AS/NZS IEC60947.1:2015 standards)