8.3. Fan Maintenance
For SOFAR 15~24KTLX-G3 series inverter with fans, if fan is broken or not working
properly may cause inverter heat dissipation issue and effect the working efficiency
of inverter. Thus, fans need to have regularly cleaning and maintain, details
operating as below:
Step 1:
Closed inverter, check the wiring side to ensure all electrical connection of
inverter is turn off ;
Step 2:
Unscrew four screws at the corner of
fans baseboard ;
Figure 8-1 remove the four screws from the fan base plate
Step 3:
Remove the screws at the fan position (1 fan for 15~17k and 2 fans for
20~24K), unplug the terminal at the fan and inverter interface and completely
remove the fan;
Figure 8-2 remove the fan and protective cover
Step 4:
Use a soft brush to clean the fan. If it is damaged, please replace it in time;
Step 5:
Re-install the inverter according to the above steps.