Other Controller Functions
Fail Safe Alerts
Clogged Line
•
In the event of a clogged line the psi reading on the main screen
will turn to stars and begin flashing. If this occurs, fix the problem
and press the middle red button to clear the code.
Broken Line
•
In the event of a broken line the psi reading on the main screen
will turn to stars and begin flashing. If this occurs, fix the problem
and press the middle red button to clear the code.
Solenoid Not Engaging (Dual Stage Systems Only)
•
In the event of a solenoid not opening to engage a second stage
of water-methanol the
psi reading on the main screen will turn to
stars and begin flashing. If this occurs, fix the problem and press
the middle red button to clear the code.
Testing the System
Step 1 Priming The System
**Before operating the system, it is recommended that the lines are
first primed with fluid and the spray pattern checked**
•
Fill reservoir with water
•
Remove the nozzle from the
intake tube.
•
With the nozzle temporarily
placed inside an empty container,
purge the system by pushing the
“prime” button (left hand button)
on the controller until fluid flows
consistently through the nozzle.
**If pump goes on and fluid level doesn't go down, there is an
obstruction in the tube or nozzle.**