161
Model: Snorkel SR9244 SR1054
Part Number: 159-0037-000
Snorkel International, LLC
2009 Roseport Road
Elwood, KS 66024
ENGINE ERRORS
5.34
The list of main engine errors that can be encountered is below (code - description).
If the engine error screen appears (see chapter 3.1.2.11), contact Snorkel service.
SPN
FMI
Blinkcode
Error Identification
523912
2
Burner dosing valve (DV2) downstream pressure sensor; plausibility error
523912
0
Physical range check high for burner dosing valve (DV2) downstream pressure; shut
off regeneration
523912
1
Physical range check low for burner dosing valve (DV2) downstream pressure; shut
off regeneration. When burner injector is actuated, the measured pressure does not
rise above ca. 1250mbar abs (expected: ca. 2400mbar).
523912
3
Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range
check high
523912
4
Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range
check low
102
2
Charged air pressure; system reaction initiated
102
2
Charged air pressure; system reaction initiated
523929
0
Fuel Balance Control integrator injector 1 (in firing order); maximum value
exceeded
523930
0
Fuel Balance Control integrator injector 2 (in firing order); maximum value
exceeded
523931
0
Fuel Balance Control integrator injector 3 (in firing order); maximum value
exceeded
523932
0
Fuel Balance Control integrator injector 4 (in firing order); maximum value
exceeded
523933
0
Fuel Balance Control integrator injector 5 (in firing order); maximum value
exceeded
523934
0
Fuel Balance Control integrator injector 6 (in firing order); maximum value
exceeded
523929
1
Fuel Balance Control integrator injector 1 (in firing order); minimum value exceeded
523930
1
Fuel Balance Control integrator injector 2 (in firing order); minimum value exceeded
523931
1
Fuel Balance Control integrator injector 3 (in firing order); minimum value exceeded
523932
1
Fuel Balance Control integrator injector 4 (in firing order); minimum value exceeded
523933
1
Fuel Balance Control integrator injector 5 (in firing order); minimum value exceeded
523934
1
Fuel Balance Control integrator injector 6 (in firing order); minimum value exceeded
523938
9
Timeout Error (BAM to packet) for CAN-Receive-Frame AT1IGCVol1 information;
factors & Sensorcalibration for NOX Sensor (SCR-system upstream cat; DPF- system
downstream cat)
523939
9
Timeout Error (BAM to BAM) for CAN-Receive-Frame AT1IGCVol1 information;
factors & Sensorcalibration for NOX Sensor (SCR-system upstream cat; DPF- system
downstream cat)