background image

8

PUSH PRO -0120843

Controls and Indicators

The operator shall know the location of each control 

and indicator and have a thorough knowledge of the 

function and operation of each before attempting to 

operate the machine. 

Figure 2 – Lower Controls and Indicators

 1.   Tilt/lowering alarm

 2.   Battery charge indicator

 3.   110V battery charger plug

 4.   Tray latch

 5.   Ground operation button

 6.   Platform raise button

 7.   Emergency stop button

 8.    Platform lower button

 9.   Control selector switch

10.  Diagnostic Port

Figure 3 – Upper Controls and Indicators

11.  Interlock button

12.  Battery condition indicator

 

LED

13.  Platform lower button

14.  Platform raise button

15.  Emergency stop button

!

Danger

Pinch points may exist between moving 

components. Death or serious injury will result 

from becoming trapped between components, 

buildings, structures, or other obstacles. Make 

sure all personnel stand clear while operating the 

aerial platform. 

•  Controls to position the platform are located on 

the lower control panel on the chassis and on the 

upper control panel in the platform.

 

Lower Controls

The lower controls (refer to Figure 2) are located on 

the right side of the chassis.
The following are located on the lower control panel:

•  Emergency stop button 

•  Control selector switch 

•  Ground operation button 

•  Platform raise/lower buttons 

•  Battery charger

!

Warning

The aerial platform is free to move when the 

brakes are released. Death or serious injury can 

result. Engage the brakes before operating the 

aerial platform.
Emergency Stop Button

The emergency stop is a two-position red push 

button. 

•  Push the button inward to disconnect power to all 

control circuits.

•  Pull the button outward to restore power.

Control Selector Switch

Insert the key into the control selector switch.

•  Turn the  switch to the lower controls position to 

operate aerial platform functions from the lower 

controls. The upper controls will not operate while 

the control selector is in the lower position.

•  Turn the switch to the upper controls position to 

operate the aerial platform functions from the 

upper controls.

•  In the center position, aerial platform functions will 

not operate from the lower or upper controls.

Controls and Indicators

2

3

6

9

5

4

7

8

1

10

12

14

13

15

11

Summary of Contents for S3006P

Page 1: ...OPERATORS MANUAL Part Number 514690 000 EN S3008P sn 01 000800 01 00231 S3010P sn 01 000500 01 00559 S3006P sn 01 000500 01 00059 S3210P sn 01 000000 01 00001 January 2020 Original Instructions...

Page 2: ......

Page 3: ...9 Platform Raise Lower Buttons 9 Pre Operation Safety Inspection 10 System Function Inspection 10 Operation 12 Preparing for Operation 12 Lower Controls 12 Upper Controls 12 Platform 13 Raising and L...

Page 4: ...42 EC This machinery also conforms to the following Directives EMC Directive 2014 30 EU The following standards have been used EN 12100 2010 EN 280 2013 A1 2015 EN 60204 1 2018 The machinery has been...

Page 5: ...rations depending upon platform occupancy rating see operators manual decals Type 3 Harness attachment point Type 3 is rated for one lanyard attachment per loop as shown in the illustrations depending...

Page 6: ...otice boards etc to the platform as this will increase wind loading IN CASE OF EMERGENCY push EMERGENCY STOP switch to deactivate all powered functions IF ALARM SOUNDS while platform is elevated STOP...

Page 7: ...PUSH PRO 0120843 5...

Page 8: ...artsinformation be sure to include the MODEL and SERIAL NUMBERS from the equipment nameplate Should the nameplate be missing the SERIAL NUMBER is also stamped on the front of the chassis Component Ide...

Page 9: ...ol button is pressed to lower the platform the alarm emits a loud beeping sound to warn personnel in the work area to stand clear Danger Pinch points exist on the scissors structure Death or serious i...

Page 10: ...d on the upper control panel in the platform Lower Controls The lower controls refer to Figure 2 are located on the right side of the chassis The following are located on the lower control panel Emerg...

Page 11: ...e emergency stop is a two position red push button on the right side of the upper control panel Push the button inward to disconnect power from all control circuits at the upper controls Twist the but...

Page 12: ...Check weekly that the fluid level in the batteries is correct See Battery Maintenance on page 15 4 Verify that the batteries are charged daily 5 Check daily that the AC extension cord has been disconn...

Page 13: ...on button inward Test each machine function from the lower control station refer to Figure 2 6 Test the emergency lowering system for proper operation 7 Push the Lower Control Emergency Stop Button to...

Page 14: ...rm Danger The aerial platform can tip over if it becomes unstable Death or serious injury will result from a tip over accident Do not exceed the capacity values indicated on the platform rating placar...

Page 15: ...elease the controls wait for three seconds then operate the controls to lower again The allarm will sound the beacon will flash and there will be a 1 5 second delay before lowering begins Any re leasi...

Page 16: ...dure to lift the aerial platform with a forklift 1 Properly stow the aerial platform 2 Engage the brakes on both of the rear wheels 3 Remove all personnel tools materials or other loose objects from t...

Page 17: ...y from the battery Always wear safety glasses when working near the battery Battery fluid is highly corrosive Thoroughly rinse away any spilled fluid with clean water Always replace the battery with a...

Page 18: ...ge drops off 9 Slide the component tray open to access the battery Remove the caps from the battery 10 Visually check the battery fluid level making sure the level is within 6 mm of the bottom of the...

Page 19: ...erating controls Proper operation Emergency stop Shuts off lower controls proper operation Lowering alarm and interrupt Sounds when platform lowers proper operation Emergency Lowering Proper operation...

Page 20: ...e to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled w...

Page 21: ...e to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled w...

Page 22: ...to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled wa...

Page 23: ...to side 1 5 degrees Front to rear 2 degrees Tires Nonmarking solid rubber Electrical System Voltage 12 V DC negative chassis ground Source One 12 V 105 amp hour battery Fluid recommended distilled wa...

Page 24: ...22 PUSH PRO 0120843 Manufacturer s Address Snorkel Europe Ltd Vigo Centre Birtley Road Washington Tyne Wear NE38 9DA UK...

Page 25: ...l Distributore locale EUROPE MIDDLE EAST AFRICA ASIA PHONE 44 0 845 1550 057 FAX 44 0 845 1557 756 NORTH SOUTH AMERICA PHONE 1 785 989 3000 TOLL FREE 1 800 225 0317 FAX 1 785 989 3070 AUSTRALIA PHONE...

Reviews: