IQOTX80/81/82/83/84/99
www.snellgroup.com
Card Edge Controls
V+ and V-
When illuminated these LED’s indicate that the positive and negative supplies
are present.
CPU
This led will flash to indicate that the CPU is running.
Input Channel Status (Ch1 to Ch8)
Off
Channel is not applicable to this product.
Yellow
SD - re-clocker locked at 270 MHz, flashes when in RC-bypass
Green
HD - re-clocker locked at 1.485/1.4835 GHz, flashes when in RC-bypass
Blue
3G - re-clocker locked at 2.97/2.967 GHz, flashes when in RC-bypass
White
(flashing) Unknown rate detected, forcing RC-bypass. Input might actually be
un-routed with all rates selected in the dialog.
Red
No signal present.
Red
(flashing)
Input detected, but rate is in error. This is as a result of the rate
selection logic on the RollCall dialogue, or the channel is un-routed and not all
rates are selected.
Error (Red)
When illuminated indicates that SFPs are fitted incorrectly or missing (see
SFP Fit Errors and Warnings).
When flashing indicates that an SFP status alarm has been activated (e.g.
temperature or supply voltage) other than the Rx Power Alarm.
Warning (Yellow)
Illuminates to indicate that the order in which the SFPs are fitted has changed
from the original documented fit (see SFP Fit Errors and Warnings).
Flashes to indicate that an SFP status warning has been activated (e.g.
temperature or supply voltage) other than the Rx Power Warning.
Good (Green)
Illuminates to indicate all SFPs are fitted and functioning correctly.