To configure a RollTrack action:
1. Select
the
Index
number. This identifies the RollTrack action being configured. Up to 32
RollTrack actions can be created.
2. From
the
Source
list, select the source of the information that will trigger RollTrack
transmission.
3.
Enter the RollTrack
Address
and click
S
. To return the address to its default value, click
the preset button (
P
).
4. Enter the RollTrack
Command
and click
S
. To return the value to its default, click the
preset button (
P
).
Viewing RollTrack Information
RollTrack Sending
and
RollTrack Status
display information about the status of RollTracks.
RollTrack Sending
displays the information when the unit is actively sending a RollTrack
command:
•
No
: The command is not being sent.
•
Yes
: The command is being sent.
RollTrack Status
displays the status of the currently selected RollTrack Index:
•
OK
: RollTrack message sent and received OK.
•
Unknown
: RollTrack message has been sent but has not yet completed.
•
Timeout
: RollTrack message sent, but acknowledgement not received. This could be
because the destination unit is not at the specified location.
•
Bad
: RollTrack message has not been sent correctly, acknowledged at the destination unit.
This could be because the destination unit is not of the type specified.
Disabled
: RollTrack sending is disabled.