Version 1 Issue 1
www.snellgroup.com
IQOTR30
Page 12
•
Reclock Bypass:
When selected, the unit will not reclock the input signal. If
a supported rate is detected, the Unit Status will display the detected rate,
otherwise, *** will be displayed.
If the
On Input Loss / Mute
option is selected, the output will be muted
whenever a recoginized rate is not detected; or, if the
On Input Loss / Pass
option is selected, any signal standard, frequency, etc… will pass through.
Output 1 / Output 2
•
Mute:
When selected, this option applies a mute on the output
•
On Input loss / Mute:
When selected, if the Input signal is lost, the output
signal will be muted.
•
On Input loss / Pass:
When selected, if the input signal is lost, it will be
passed unchanged.
Fiber Optic Tx 1
This section displays the following information about the fiber optic output signal:
•
Tx Wavelength
•
Laser Bias
•
Laser Bias State
•
Tx Power
•
Tx Power State
•
Laser OFF:
Selecting this option disables the laser.
•
Laser OFF - On Input Loss:
Selecting this option disables the laser if the
input signal is lost.
Fiber Optic Rx 2
This section displays the following information about the fiber optic input signal:
•
Rx Power
•
Rx Power State
These controls only apply to the SDI outputs on the BNC. The laser
output is controlled by the Laser OFF and Laser OFF - On Input
Loss controls.
These controls only apply to the fiber optic output signal. The SDI
outputs on the BNC are controlled by the Mute and On Input Loss
- Mute controls.
When the unit is forced to a particular standard, the laser controls
are not grayed out, and the laser will still be active if an incorrect
standard is applied unless Laser OFF - On Input Loss is selected.
Note:
Note: