IQBRK00/01
B12
IQBRK00OPS 05/04/07
www.snellwilcox.com
Version 1 Issue 6
B12.48
◀
◀
◀
◀
Monitor
The four audio buses are monitored and level
detectors provide status information and logging
data.
Chroma_B/W
Monitor
Silence Level
Low Level
High Level
Overload Level
Warning Timer
Levels
Levels
-32.0 dB
Preset
Levels
These levels may be adjusted by rotating the
spinwheel.
◀
Silence Level
The level at which the signal is considered to have
dropped to silence may be set with this control.
The range is from -80 dB to 0 dB in steps of 1 dB.
Preset is to -70 dB.
◀
Low Level
The level at which the signal is considered to have
dropped to a Low Level may be set with this
control.
The range is from -80 dB to 0 dB in steps of 1 dB.
Preset is to -60 dB.
◀
High Level
The level at which the signal is considered to have
risen to a High Level may be set with this control.
The range is from -80 dB to 0 dB in steps of 1 dB.
Preset is to -10 dB.
◀
Overload
The level at which the signal is considered to have
risen to an Overload condition may be set with this
control.
The range is from -80 dB to 0 dB in steps of 1 dB.
Preset is to 0 dB.
◀
◀
◀
◀
Warning Timer
All the above monitoring facilities will only operate
after a time interval set by this control. When OK it
will operate immediately.
Warning Timer
14 sec
Preset
Warning Timer
The range is from 1 to 20 seconds. Preset is to 10
seconds.