background image

IQADA01                 

SECTION N34 

 

IQADA01OPS  19/04/2007 

www.snellwilcox.com 

Version 1 Issue 1 

N37.10 

RollCall PC Control Panel Screens

 

 

Setup 

 
 

Note  that  for  this  and  other  screens  the  following 
applies to the scroll bars: 

 

The 

  and 

  symbols  at  the  ends  of  the  scroll 

bar allow the value to be adjusted in discrete steps.  
 
The numerical value will be shown above the scroll 

bars  and  selecting  Preset 

  will  return  the 

setting to the calibrated value for that item. 
 
 

Gain 1 and Gain 2 

 
When  configured  as  a  dual  input  amplifier  these 
controls allow the gain of the two input channels to 
be adjusted.   
The  range  is  ± 24 dB  in  steps  of  0.5 dB.  Preset  is 
to –0.0 dB. 
 

Note that when configured as single input amplifier 
only the Gain 1 control will be available. 

 

Silence Level 

 
The level at which the signal is considered to have 
dropped to silence may be set with this control. 
 
The  range  is  from  -25 dB  to  -15 dB  in  steps  of 
1 dB. Preset is to -20 dB. 
 

Silence Detect Time 

 
The  Silence  Level  detect  facility  will  only  operate 
after  a  time  interval  set  by  this  control.  A  valid 
signal is reported immediately.  
The range is from 1 to 60 seconds. Preset is to 10 
seconds. 
 

 

 
Selecting  this  item  sets  all  adjustment  functions 
that include a preset facility, to their preset values. 

 

 

 

This  will  reboot  the  unit  simulating  a  power-down 
power-up cycle restoring power-up settings. 

 

 

 

Software version 

 
This  item  shows  the  version  of  the  software  fitted 
in the module. 

 
Serial Number 

 
This item shows the serial number of the module 
 

Build Number 

 
This  will  indicate  the  factory  build  number.  This 
number defines all parameters of the unit (software 
versions, build level etc.) for identification purposes 
 

Summary of Contents for IQADA01

Page 1: ...atures 4 Technical Profile 5 INPUT AND OUTPUT CONNECTIONS 6 Analog IN 6 Analog OUT 6 25 Way D Type Connection Details for Connector 1 and Connector 2 7 CARD EDGE INDICATORS 9 RollCall PC Control Panel...

Page 2: ...0 1A Single Dual Channel Analog DA Balanced D type Audio Connections Configurable for 1 input to 14 outputs or 2 inputs to 7 outputs per input IQADA0112 2 Single Dual Channel Analog DA Balanced D type...

Page 3: ...style enclosure shown below IQ Enclosure order codes IQH3A E 0 IQH3A E P IQH3A 0 0 IQH3A 0 P Enclosure order codes IQH3A S 0 IQH3A S P O Style Enclosures Rear panels without the suffix A may only be...

Page 4: ...work control monitoring intelligence and 2 Built in Intelligence 1 1 2 3 Silence Detect Gain Silence Detect Gain 4 5 6 7 1 2 3 4 5 6 7 Features Configurable for 1 input to 14 outputs or 2 inputs to 7...

Page 5: ...stable for each input Functions Available via RollCall Gain Separate L and R 24 dB to 24 dB in 0 5 dB steps Silence Detect Level adjustable 15 to 25 dBu in 1 dB steps Warning Timer 1 to 60s for silenc...

Page 6: ...e connectors For connection data consult the tables on page 7 Note that when configured as a single input fourteen output amplifier connector 1 should be used for the input signal Analog OUT All balan...

Page 7: ...tput 2 23 Ground 7 Ground 24 Channel 7 Analog Audio Output 1 25 Channel 8 Analog Input By Function Pin No Description Connection 1 Chassis Ground Ground 2 Channel 1 Analog Audio Output 7 15 Channel 1...

Page 8: ...ectors MALE CONNECTOR OUTPUTS FEMALE CONNECTOR INPUTS 25 Way Male D Type XLR Connections Solder Pin Side 16 19 22 25 2 5 8 11 1 3 4 6 7 9 10 12 13 14 15 17 18 20 21 23 24 XLR Connections Analog Audio...

Page 9: ...inate if either input or the primary input when in single channel mode is missing D3 Power up or CPU fault Red This LED will illuminate during power up or indicate a CPU fault RV1 and RV2 These contro...

Page 10: ...available Silence Level The level at which the signal is considered to have dropped to silence may be set with this control The range is from 25 dB to 15 dB in steps of 1 dB Preset is to 20 dB Silenc...

Page 11: ...t the status of the unit Input 1 and Input 2 This will show the status of the input It can show SILENCE The input signal has been lost OK The module is receiving a valid input signal Mode Shows whethe...

Page 12: ...to the right of the item Any of the items may be selected from the list ROLLCALL LOG FIELDS Where Applicable Log Field Log Value Description INPUT_1_STATE OK WARN Silence Status of the input signal IN...

Page 13: ...his item allows the address of the selected destination unit to be set To change the address type the new destination in the text area and then select return Preset returns to the default destination...

Page 14: ...rack destination not in use String A string value is always being sent Number A number value is always being sent No The message is not being sent Yes The message is being sent Internal Inconsistent b...

Page 15: ...o LCD windows Operational details for the remote control panel can be found in the Modular System Operator s Manual Information Window The Information window has four lines of text indicating the curr...

Page 16: ...Index RollTrack Command RollTrack Command 0 Clear Preset OK RollTrack Sending Status RollTrack Sending Status YES OK RollTrack Address RollTrack Address 0 Clear Preset OK Unit Software Version Serial...

Page 17: ...more information MAIN MENU IQADA01 MENU Setup RollTrack Logging Setup This allows various functions to be setup Setup Setup Gain 1 Gain 2 Silence Level Silence Detect Time Unit Gain 1 and Gain 2 When...

Page 18: ...t Selecting this item sets all adjustment functions that include a preset facility to their preset values Note that this is a momentary action Restart This will reboot the unit simulating a power down...

Page 19: ...ng an item in this menu the status of the item will be shown in the display window Status INPUT_2_TYPE INPUT_2_IDENT INPUT1 INPUT_1_TYPE INPUT_1_IDENT INPUT2 Display Window Logging Status Items Loggin...

Page 20: ...all RollTrack items will be disabled RollTrack Address This item allows the address of the selected destination unit to be set RollTrack Address RollTrack Address 0 Clear Preset OK To compile edit th...

Page 21: ...This may show String A string value is always being sent Number A number value is always being sent No The message is not being sent Yes The message is being sent Internal Inconsistent behavior pleas...

Page 22: ...IQADA01 SECTION N34 IQADA01OPS 19 04 2007 www snellwilcox com Version 1 Issue 1 N37 22 Manual Revision Record Date Version No Issue No Change Comments 18 Apr 07 1 1 First Issue released...

Reviews: