49
Diagnostics
Retrieve additional data by clicking on the
target identification icon. The information
displayed depends on the type of camera
being used (Ultra or Ultra UHR)
Threshold -
All pixels received by the
cameras have a brightness level of 0 to
255. Threshold tells the cameras to ignore
any pixel with a brightness level below
a certain number. Threshold levels are
software controlled and are primarily for
engineering use.
Acquire Count
- How many images it takes
to acquire a target.
Number of Planes
- Number of target
planes that the camera has acquired.
Number of Images
- Number of raw im-
ages that the camera has acquired.
The user can quickly jump to each targets information by clicking on the target
identification icon. This screen will display warning indications if any of the
following criteria have been exceeded or if a target is not visible.
•
Target angle greater than 48 degrees.
•
Distance to front target greater than 160 inches (4.064 meters).
•
Distance to rear target greater than 240 inches (6.096 meters).
•
Target RMS greater than 0.10.
• Number of target blobs is specific to the type of target being used.
•
Number of images is 0 for a particular camera.
•
Number of planes is 0 for a particular wheel..
NOTE: CLICK ON “BACK” BUTTON TO
EXIT ALL TESTS!
The Data Examination Screen offers a few
more diagnostic tools to troubleshoot the
UHR cameras. Most of this information is
used by engineering in development.
Summary of Contents for UHR Ultra
Page 1: ...Service Manual Ultra UHR Ultra and V3400 WHEEL ALIGNER May 2014 ...
Page 13: ...11 AC DC POWER DISTRIBUTION ...
Page 14: ...12 AC DC POWER DISTRIBUTION ...
Page 16: ...14 Theory of Operation Figure 2 Top Field of View Figure1 Side Field of View ...
Page 19: ...17 Theory of Operation Configuration using single pole wheel clamp ...
Page 46: ...44 NOTES ...
Page 67: ...65 Diagnostics ...
Page 68: ...66 NOTES ...
Page 83: ......
Page 84: ...05 07 2014 2014 Impreso en U S A 309 Exchange Avenue Conway AR 72032 TEEWA546P4 Rev C ...