• 26 •
CHARGE
From the MANUAL PROCEDURE, select CHARGE, the following
screen will be displayed:
If HYBRID VEHICLE is selected the machine will perform
FLUSHING HOSES (Refer to Manual Procedure section, pg 24,
FLUSHING HOSES), then the following screen will be displayed:
NOTE
: press g, lb, or lb/oz to change the weight measurement
units.
EDIT CHARGE DATA
NOTE:
For most systems the quantity of fluid to be refilled is
indicated on a plate that is in the vehicle’s engine compartment.
If this quantity is not known, look for it in the relevant manuals.
Select CHARGE value box, then use the keys 0 to 9 to type the of
refrigerant to be charged into the A/C system.
NOTE:
If DATABASE is installed, it can be used to insert the value
of refrigerant into the CHARGE field.
NOTE:
If charge amount is lower than 4 oz (100 g) the following
popup warning will be displayed:
Charge amount lower than 4 oz (100 g) is not allowed, press
ENTER then re-enter a higher CHARGE AMOUNT value.
EDIT CHARGE MODE
Select the connection mode:
HP+LP fill the refrigerant from both HP and LP service
ports.
HP to fill the refrigerant only from the HP service port.
LP to fill the refrigerant only from the LP service port.
START PROCEDURE
After all CHARGE data is selected, press ENTER to continue, the
following screen will be displayed:
Type the plate of the car, press ENTER to confirm. ESC to return
back.
NOTE:
the numerical keys include an alphabet that is used
similar to text messaging; for example: press “2” once to display
“2”, twice to display “A”, three times for “B”, four times for “C”, five
times for “a”, six times for “b”, seven times for “c”, eight times for
“2” again.
Connect and open the coupling (HP, LP, or HP/LP, depend of the
previous choice) connected to the A/C system, then press ENTER.
Press ESC to return back.
The machine will perform 5 minutes of vacuum:
At the end of this phase, the machine will test for leaks in the A/C
system:
R1234yf
MANUAL PROCEDURE
VACUUM
inHg
A/C Pressure
The use of PAG OIL
or DYE in hybrid
cars may damage
compressor!
Please use only
recommended oil.
R1234yf
MANUAL PROCEDURE
Hybrid vehicle
Standard vehicle
Connect and open HP and LP coupling to A/C
system Press ENTER
R1234yf
MANUAL PROCEDURE
CHARGE
Inset vehicle
Plate number:
___________________
R1234yf
MANUAL PROCEDURE
CHARGE
1
2
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PQRS
8
TUV
9
WXYZ
0
|_|
←
.,
WARNING !
charge amount
Less than 100g/4oz
Press ENTER to continue
R1234yf
MANUAL PROCEDURE
CHARGE
R1234yf
MANUAL PROCEDURE
CHARGE AMOUNT
DATABASE
HP+LP
LP
HP
xx
lb
lb
lb/oz
g