• 21 •
Put the leak detector on rear evaporator outlet and search for
leaks, then press ENTER to continue:
A pop-up message is displayed asking confirmation, press YES to
continue:
Press NO if no leak was found, upon completion of the PRE-
CHARGE TEST, the system will go on to charging with the preset
quantity of refrigerant.
Then the following screen will be displayed:
Disconnect HP coupling, Start A/C system with LP coupling
connected, press ENTER.
The A/C system will recover the refrigerant into the service hoses,
then the following screen will be displayed:
Disconnect LP coupling from A/C system, then press ENTER to
continue:
The machine will recover the residual refrigerant into the service
hoses, then the following screen will be displayed
:
Procedure is now successfully completed.
Press PRINTER to print the receipt of the procedure. Press ENTER
to exit.
NOTE:
The automatic procedure may be run even if the A/C
system is empty. In this case, the machine will begin with the
vacuum phase.
Was a leak found?
YES
NO
R1234yf
AUTOMATIC PROCEDURE
PRE-CHARGE TEST
Was an auxiliary
evaporator check
performed?
YES
NO
R1234yf
AUTOMATIC PROCEDURE
PRE-CHARGE TEST
R1234yf
AUTOMATIC PROCEDURE
xx
psi
EMPTY HOSES
Empty hoses
Hoses pressure
R1234yf
AUTOMATIC PROCEDURE
CHARGE
Disconnect LP coupling, from A/C system and
Press ENTER
Disconnect HP coupling Start A/C system with LP
coupling connected and press ENTER
R1234yf
AUTOMATIC PROCEDURE
CHARGE
R1234yf
AUTOMATIC PROCEDURE
EMPTY HOSES
End Of Procedure
Gas recovered xxx lb
Oil discharged xxx oz
Vacuum time xxx min
Gas charged xxx lb
Press ENTER to continue
Gas charged
Tank Pressure
A/C pressure
Tank temperature
R1234yf
AUTOMATIC PROCEDURE
CHARGE
lb
psi
psi
°F
Summary of Contents for POLARTEK YF EEAC333
Page 2: ... 2 ...
Page 4: ... 4 REPLACING THE PRINTER PAPER 44 INFO 44 WARRANTY 45 NOTES 46 ...
Page 46: ... 46 NOTES ...
Page 47: ... 47 ...