• 40 •
EMPTYING THE USED OIL CONTAINER
Procedure:
Open the upper door on the right side (ref 4, Fig. 37).
Press quick connection button (ref 1, Fig. 37) to disconnect the
used oil container.
Lift the used oil container out of its lodging (ref n, Fig. 37) without
exerting pressure on the scale.
Unscrew the cap (ref 2, Fig. 38) while holding the container.
Empty the used oil into a suitable container for used oils (Fig. 39).
Screw the cap back into the container.
Replace the container and hook it up to the quick connection
taking care not to exert pressure on the scale in order not to
damage it.
NOTE:
In order to avoid damage to the oil scale, never exert
pressure on it either from above or from below.
1
n
4
FIG. 37
FIG. 39
FIG. 38
2