• 20 •
When completed, the system will go on to charging with the
preset quantity of refrigerant.
Then the following screen will be displayed:
Disconnect HP coupling, Start A/C system with LP coupling
connected, press ENTER.
The A/C system will recover the refrigerant into the service hoses,
then the following screen will be displayed:
Disconnect LP coupling from A/C system, then press ENTER to
continue:
The machine will recover the residual refrigerant into the service
hoses, then the following screen will be displayed
:
Close HP and LP side valves then press ENTER to continue:
Procedure is now successfully completed.
Press ENTER to exit.
NOTE:
The automatic procedure may be run even if the A/C
system is empty. In this case, the machine will begin with the
vacuum phase.
R134a
AUTOMATIC PROCEDURE
EMPTY HOSES
Close HP and LP side valves and press ENTER
R134a
AUTOMATIC PROCEDURE
CHARGE
Disconnect LP coupling from A/C system and press ENTER
R134a
AUTOMATIC PROCEDURE
EMPTY HOSES
End Of Procedure
Gas recovered xxx lb
Oil recovered xxx oz
Vacuum time xxx min
PAG injected xxx oz
Gas charged xxx lb
Press ENTER to continue
R134a
AUTOMATIC PROCEDURE
xx
psi
EMPTY HOSES
Empty hoses
Hoses pressure
Disconnect HP coupling Start A/C system with LP
coupling connected and press ENTER
R134a
AUTOMATIC PROCEDURE
CHARGE
Gas charged
Tank Pressure
A/C pressure
Tank temperature
R134a
AUTOMATIC PROCEDURE
CHARGE
lb
psi
psi
°F
Oil Injected
R134a
AUTOMATIC PROCEDURE
PAG INJECTION
oz
Summary of Contents for POLARTEK EEAC330
Page 2: ... 2 ...
Page 4: ... 4 INFO 41 WARRANTY 42 NOTES 43 ...
Page 43: ... 43 NOTES ...
Page 44: ... 44 ...
Page 45: ... 45 ...