51 of 73
- ISOLATION AND VERIFICAITON PROCEDURES:
ISOLATION AND VERIFICATION PROCEDURES:
ENERGY TYPE
AND SOURCE
LOCKOUT
LOCATION
(TO BE COMPLETED
BY END USER)
PROCEDURE FOR LOCKING OUT
AND OR RELEASING ENERGIES
VERIFY PROCEDURES
STORED
ENERGY
AND
HYDRAULIC
PRESSURE
3000-5000
PSI
LOWER THE LIFT TO ITS LOWEST
REST POSTION. IF THE LIFT MUST
BE SERVICED OR MAINTAINED IN
THE RAISED POSITION, ENSURE
THAT THE LIFT IS PLACED ON THE
MECHANICAL LOCKS AND
SUPPORTED BY SUPPLEMENTARY
JACK STANDS, BLOCKED AT THE
SLIDERS AND A COME ALONG
SECURED BETWEEN THE
SCISSORS.
VERIFY THAT THE LIFT IS
CONTACTING THE
SUPPLEMENTARY JACK STANDS,
THE BLOCKS ARE SECURLY
PLACED AND THE COME ALONG IS
SECURED BETWEEN THE
SCISSORS.
PRESS THE DOWN BUTTON ON
THE CONSOLE AND VERIFY THAT
THE LIFT DOES NOT LOWER.
VERIFY HYDRAULIC PRESSURE
HAS BEEN REMOVED BY SLOWLY
OPENING THE MAIN HYDRAULIC
FITTING AT THE POWER UNIT
ONLY. IF FLUID IS PRESENT UNDER
PRESSURE, IMMEDIATLY TIGHTEN
AND REPEAT LOWER PROCESS.
ENSURE THAT BOTH STRUCTURES
ARE SECURELY PLACED ON THE
STANDS AND BLOCKED.
ELECTRICAL
240VOLTS
AT THE LIFT, PRESS THE
EMERGENCY STOP BUTTON
COMPLETELY TO DE-ENERGIZE THE
CONTROL BUTTONS.
AT THE DISCONNECT PLANEL,
PLACE THE DISCONNECT HANDLE
IN OFF POSITION. ATTACH A
MULTIPLE LOCKOUT DEVICE.
LOCK AND TAG.
DANGER:
LINE SIDE OF DISCONNECT
REMAINS ENERGIZED
ATEMPT TO RESTART THE
SYSTEM, THE SYSTEM MUST NOT
START. VISUALLY VERIFY OPEN
DISCONNECTS AND LOCKING
DEVICE INSTALLED.
ADD A VOLTMETER CHECK TO
ENSURE THAT THE INPUT POWER
SOURCE HAS BEEN
DISCONNECTED.
PNEUMATIC
UPTO
160PSI
SLOWLY CLOSE LOCKOUT VALVE
TO RELEASE AIR PRESSURE
GRADUALLY. ATTACH MULTIPLE
LOCKOUT DEVICE, LOCK AND TAG.
DANGER:
LINE SIDE OF DISCONNECT
REMAINS PRESSURIZED
VERIFY THE VALVE IS CLOSED AND
LOCKOUT DEVICE IS PROPERLY
ATTACHED. OPERATE THE
PNEUMATIC SYSTEM TO ENSURE
THE SYSTEM IS DE-ENERGIZED.
IT MAY BE NECESSARY TO BLEED
THE SYSTEM OF REMAINING
COMPRESSED AIR, THIS CAN BE
PERFORMED AT THE BASE OF THE
WATER SEPARATOR BOWL.
Summary of Contents for EELR501A
Page 6: ...6 of 73 2 0 SAFETY WARNING DECALS...
Page 8: ...8 of 73 Figure 2 Lift Dimensions Side View Figure 3 Lift Dimensions Back View...
Page 18: ...18 of 73 Figure 12 Hydraulic Connections...
Page 33: ...33 of 73 Figure 31 Connection of Air Recoil Hose...
Page 64: ...64 of 73 16 6 Air Line Routing Map Figure 53 Air Hose Assembly...
Page 69: ...69 of 73 17 5 Console Labeling Figure 57 Console Labeling...