4.
Faults
First Step:
Open the unplugged unit. Plug the unit in; check the display. Start the ENTERPRISE TC4 unit and check if there is fog or not. I
f so check the consistency (not
wet) and the smell (not pungent) of the fog. It can take a while before the unit is working normal because of unsteady fluid le
avings in the tubes. First listen if the
fluid pumps start, is fluid escaped somewhere, does the heat exchanger heat up,
maybe there is an apparent fault.
Be careful because of the 230V and
the heat
. Is the defect part apparent, have closer look to this and do the testing as described in the appropriate chapter below. Is it
more difficult to locate the
fault
,
follow the steps in the table below.
4.1
Description of general faults
No.
F
ault
Identification
Testing
R
esult
Repair
1.1 PCB ENTERPRISE TC4:
1.1.1 Check the power connection at the board (PIN
X1:4/5)
Power
No Power
Proceed with 1.2
Exchange the board
1.1.2 Check the fuse, continuity test
No continuity
Continuity
Exchange the fuse
Proceed with 1.3
1.
No power
after plugging
in of the
power supply.
Display remains
dead
1.1.3 Check if something is burned at the board
Burned
Not burned
Exchange the board
Check if there is fluid/ humidity, if so dry
carefully
2.1 Check the pumps, maybe
one or both
are
broken (see test plan below)
One is not working
Both are working
Change the broken device
Proceed with 2.2
2.2 Check the heat exchanger, maybe it is/ they are
clogged or partial clogged (see test plan below)
One is not working
Both are working
Change the broken device
Proceed with 2.3
2.3 Check the tube connections/fittings, maybe one
is disconnected
Everything is connected properly
Some tubes are disconnected
Proceed with 2.4
Reconnect the disconnected tubes
2.
Power
available, less
fog/ approx.
the half or no
fog
Display is ok but no
„normal“ fog/ less
fog or no fog.
2.4 Check the fog fluid, maybe it's nearly empty
Fog fluid is sufficient available
Fog fluid is almost empty
Check the power supply (see test plan
below)
Change the fog fluid bottle
3.
Various faults:
E4, wet fog,
overheat,
wrong display,
etc.
Unit is wet from the
inside with fog
fluid, boards are
wet
This fault is apparent, no testing is necessary.
Take machine to pieces and clean each component!
Heater is leaking internally
Cooling air was to foggy
Broken pressure pipe
The heater needs to be changed.
Change location
Change pipe
ENTERPRISE TC4 – SERVICE MANUAL
9
SMOKE FACTORY