2
ENTERPRISE TC4 – SERVICE MANUAL
SMOKE FACTORY
FOG & HAZE GENERATORS
1. Introduction
1.1 General
This document should be used if ENTERPRISE TC4 is not working properly. With this document it
should be possible to find the fault/ not working device and change this device without the direct help
of the manufacturer.
ENTERPRISE TC4 has two pumps and thermocouples (2400W heater) and a connector for an
external fan. ENTERPRISE TC4 is available for 230V/
50Hz
.
1.2 Danger
-
While replacing any device the power plug should be unplugged.
-
While testing
under life conditions
(230V), never touch blank contacts.
2. Components
2.1
Pump EX5 230V/50Hz (50172), 120V/60Hz (59019)
Picture 2.1: Pump EX5 230V/50Hz (50172)
2.2
HE 2400 Heat Exchanger (part number 69022)
Picture 2.2.1b: Power connection
Picture 2.2.1a: HE2400 Heat Exchanger – ENTERPRISE TC4 (69022)
Thermostat
X1:3
X1:6