SMK P100AC Operator'S Safety And Service Manual Download Page 6

Page 11 

!

   

 

C A U T I O N

   

 

!

 

IT IS YOUR RESPONSIBILITY TO ENSURE THAT THE 
MATERIAL YOU ARE SPRAYING IS COMPATIBLE WITH 
THE PUMPS COMPONENTS. 

!

   

 

C A U T I O N

   

 

!

 

If the product being sprayed is intended to cure or 
set up after application, the Sprayer must be 
cleaned.  Flush with Xylene for 60 seconds or more. 
Leave Xylene in pump until next use. Failure to 
clean the unit after using these types of materials 
will result in failure of the unit and loss of warranty 
coverage. 

Do not run dry or use abrasives 

Never use without Intake Filter 

If Switch light flickers, reduce pump speed 

Attempting to spray liquids below the manufactures 
recommended temperatures may affect the sprayers 
ability to adequately perform. Low temperatures 
may affect your materials viscosity. 

Do not submerge or expose to excessive moisture 

Do not spray liquids with high solids (0ver 35%) or 
abrasive additives as this will destroy the pumps 
gears and will void the warranty. This Sprayer is 
intended for and was tested with Chemicals used for 
curing and sealing applications. If you are unsure of 
the suitability of the product you want to spray 
contact SMK at 515-202-0052 for assistance.   

Page 4 

Warranty 

!

   

 

C A U T I O N

   

 

!

 

DO NOT ATTEMPT TO SERVICE THE UNIT BY REMOVING 

THE COVER. REMOVAL OF THE UNIT COVER WILL VOID 

THE WARRANTY. CALL THE SERVICE CENTER.

 

SMK Industries warrants this product to be free from 
material or workmanship defects for a period of 60 days 
from the date of manufacture. Alternatively, 60 days from 
purchase, not to exceed one year from date of 
manufacture. 
Warranty does not apply when: 

Unit is not used within the guidelines of this 
manual. 

Product or Parts are used or installed outside 
the SMK authorized service center. 

Incompatible fluids are used. 

Misuse or Abuse. 

Improper or inadequate cleaning of unit after 
use. 

In the event you need to utilize this warranty, the product or 
part must be returned for examination, postage prepaid, 
direct to the SMK Industries service center as instructed by 
calling 515-202-0052.  Proof of purchase date and an 
explanation of the claim must accompany the 

Summary of Contents for P100AC

Page 1: ... Copyright 2014 SMK Industries Inc Operator s Safety and Service Manual Cordless Sprayer Model P100AC ...

Page 2: ...100AC portable sprayer utilizes a magnetically coupled gear pump and 1 DeWalt NiCad or Lithium Ion 18V battery SMK reserves the right to make changes to this manual without notice Table of Contents Safety Information 2 Introduction 2 Safety Precautions 3 4 Warranty 5 Proof of purchase 6 Specifications 6 Operation 7 Contents of carton 7 Assembly 8 9 Operating the sprayer 10 Clean up 11 Chemical com...

Page 3: ...nd the service center nearest you Call 1 515 202 0052 For a list of replaceable parts please call 515 202 0052 for assistance Page 13 Safety Information Introduction This Safety Alert Symbol is used to call attention to items or operations which may be dangerous to those operating or working with this equipment The symbol can be found throughout this manual Please read these warning and cautions c...

Page 4: ...f all dangers present near SMK equipment If you are operating SMK equipment it is your responsibility to insure that such operation is in full accordance with all applicable safety requirements and codes All requirements of the United States Federal Occupational Safety and Health Administration Act must be met when operated in areas that are under the jurisdiction of the United States Department P...

Page 5: ...e or set up after application the Sprayer must be cleaned and flushed after EACH use Flush with Xylene for 60 seconds or more Leave Xylene in pump until next use Failure to clean the unit after using these types of materials will result in failure of the unit and loss of warranty coverage DO NOT USE THE PUMP TO PURGE THE SPRAY HOSE Running the Pump dry over 1 minute will destroy the gears and void...

Page 6: ...y This Sprayer is intended for and was tested with Chemicals used for curing and sealing applications If you are unsure of the suitability of the product you want to spray contact SMK at 515 202 0052 for assistance Page 4 Warranty C A U T I O N DO NOT ATTEMPT TO SERVICE THE UNIT BY REMOVING THE COVER REMOVAL OF THE UNIT COVER WILL VOID THE WARRANTY CALL THE SERVICE CENTER SMK Industries warrants t...

Page 7: ...the Speed Control down counterclockwise until the light is steady on pump is not cycling on and off e After liquid is flowing and all air is purged from the lines release the Handle and the Sprayer will turn off f If the pump does not prime within 20 seconds turn off the power and check to see that all fittings are tight and the Intake Filter is not clogged g Running the Pump dry over 1 minute wil...

Page 8: ...ssume obligation or liability on behalf of SMK Industries Inc Products and parts must be flushed free of all fluids prior to returning to SMK for warranty inspection PROOF OF PURCHASE Please retain your dated sales receipt as proof of purchase to validate the warranty period SPECIFICATIONS Pump TOPSFLO MG213XK DC24WI Pump Voltage 24 Volts Chassis Powder Coated Steel Spray Gun TeeJet AA30L 1 4 Wand...

Page 9: ...epare the unit for operation assemble the sprayer as follows 1 Spray Tip a The Wand comes preassembled with an Adjustable Cone Tip b An optional 0 1 GPM Tapered Fan tip and Check Valve with Screen is provided in a Shipping Bag 2 Assemble Spray Hose a Attach Spray Hose to the Spray Gun and Sprayer Unit Both ends are the same b Slide the spring loaded knurled collar on the Hose Coupler towards the H...

Reviews: