SPRAYER WILL NOT START
✓
If battery is not properly seated and fully charged
✓
If On/Off switch is in the off position
✓
If Speed Control is turned off (counterclockwise)
SPRAYER WILL NOT PRIME
✓
If pickup tube or discharge hose is restricted
✓
If Spray tip or Filter on end of Wand is plugged
✓
If you are out of product
✓
For properly charged battery(s)
✓
For vacuum leak in suction tube
SPRAYER OUTPUT VOLUME REDUCED
✓
If pickup tube or discharge hose for restrictions
✓
Sprayer wand and wand tip for restrictions
✓
Material is too high in viscosity
✓
Material is too cold
Page 12
Clean up
!
C A U T I O N
!
As with any type of sprayer, this unit will not function
satisfactorily if the unit is not clean. If the product being
sprayed is intended to cure or set up after application, the
Sprayer must be cleaned and flushed after EACH use.
Flush with Xylene for 60 seconds or more. Leave Xylene in
pump until next use.
Failure to clean the unit after using these types of materials
will result in failure of the unit and loss of warranty
coverage.
DO NOT USE THE PUMP TO PURGE THE SPRAY
HOSE. Running the Pump dry over 1 minute will destroy
the gears and void the warranty. Disconnect the Hose on
each end and drain manually using gravity.
Chemical Compatibility
The magnetically coupled gear pump has no seals or
gaskets in the fluid path and therefore will not leak. The
only material coming in contact with the fluid being sprayed
is 316 Stainless Steel, Ceramic and PEEK
(Polyetheretherketone) Gears.
The only solvents which will attack PEEK are concentrated
nitric acid and sulphuric acids.
Muriatic/Hydrochloric Acid must be limited to 30% to
prevent damage to Polypropylene Inlet Filter.