CADD

®

-Solis VIP  

Ambulatory Infusion Pump 

Quick Start Guide

A

  Battery Compartment

B

  Display

C

  Indicator Lights

D

  USB Port

E

  Blue AC Power Light

F

  AC Power Jack

 Remote Dose Cord Jack

 Keypad

  Cassette Latch

  Help Messages

 Cassette/Keypad Lock

 Power Switch

Summary of Contents for CADD-Solis VIP

Page 1: ...ulatory Infusion Pump Quick Start Guide A Battery Compartment B Display C Indicator Lights D USB Port E Blue AC Power Light F AC Power Jack G Remote Dose Cord Jack H Keypad I Cassette Latch J Help Messages K Cassette Keypad Lock L Power Switch ...

Page 2: ...argeable battery pack Turn on the pump using the power switch on the side of the pump To start programming select Tasks Press to highlight View Advanced Tasks then press select PROGRAMMING A NEW PATIENT Power switch to turn pump on off OR Tasks 02 ...

Page 3: ... each digit then press select to confirm and advance to the next digit Once the complete 3 digit code has been entered press Accept Value Highlight the appropriate therapy PCA Continuous Intermittent Step Taper by pressing or then press select to confirm Next highlight a qualifier by pressing or then press select to confirm ...

Page 4: ... settings then appear on the screen To confirm a setting press Accept Value the symbol appears on the left Then highlight the drug by pressing or and press select to confirm A screen asking you Are these correct appears To confirm select YES or to cancel select NO ...

Page 5: ...pump will then explain to you how to prime the tubing Once priming is complete the pump will ask if you want to start delivery Press Yes to start To edit the highlighted delivery setting press select Next adjust the value by pressing or then select Save Confirm your choice by pressing Accept Value the symbol appears on the left When you have confirmed all of the settings press Next ...

Page 6: ...ou want to edit and enter the keypad code to continue You can then edit the value using the or keys and press Save to confirm 5 Your modification has been saved Press the Stop Start key 6 The pump then asks you to Review pump settings select Review 7 You must then confirm each item the symbol appears by each item acknowledging your confirmation 8 Once confirmation is compete the pump displays the ...

Page 7: ...n it clockwise to lock the cassette if using PCA mode 6 When set to PCA mode you must lock the cassette in order to be able to start delivery To lock the cassette insert the key into the cassette keypad lock and turn clockwise Correct Incorrect An uneven gap indicates that the cassette is not properly latched REMOVING THE CASSETTE OR TUBING 1 Make sure that delivery has stopped and clamp the tubin...

Page 8: ... key 2 Remove the disposable 3 Attach the new disposable 4 Switch on the pump 5 Press the button just below Tasks 6 Using the key scroll down until the white box highlights View Delivery Settings then press select 7 Using the key scroll down until the white box highlights Reservoir Volume then press select 8 Enter the security code 9 Next press or to select the new reservoir volume then press Save...

Page 9: ...1 In the Tasks menu press or to select Prime tubing and press select unlock the keypad if necessary 2 Select Prime 3 Once you have pressed Prime you do not need to hold your finger down on the key 4 Once priming is complete and the air is removed from the line select Stop Priming I WANT TO PRIME THE TUBING The reports can be viewed at any time whether the pump is running or stopped 1 In the Tasks ...

Page 10: ...e then press select to confirm 3 Set the desired delivery start time then select Confirm 4 A confirmation screen will appear displaying the delivery start time To confirm select Yes or to cancel select No 5 Start delivery by pressing the Stop Start Tasks 02 key a delayed start screen will appear Note the delivery start time will now be visible in the delivery settings To view these settings go to ...

Page 11: ...A doses but not clinician boluses within a specified time frame between 1 hour and 12 hours Max Doses Hr Maximum number of PCA doses allowed within a 1 hour period KVO Rate The KVO Keep Vein Open function allows the delivery of a minimal amount of drug to help maintain catheter patency Reservoir Vol Reservoir volume cassette or bag Start Time If a delayed start is programmed the delivery start tim...

Page 12: ...he infusion volume Plateau Rate Maximum rate at which medication is delivered This rate is automatically calculated by the pump KVO Rate The KVO Keep Vein Open function allows the delivery of a minimal amount of drug to help maintain catheter patency Reservoir Vol Reservoir volume cassette or bag Start Time If a delayed start is programmed the delivery start time is indicated TAPER MODE TPN TOTAL ...

Page 13: ...tion KVO Rate The KVO Keep Vein Open function allows the delivery of a minimal amount of drug to help maintain catheter patency Reservoir Vol Reservoir volume cassette or bag Start Time If a delayed start is programmed the delivery start time is indicated CONTINUOUS MODE Gray screen ...

Page 14: ... dose Dose Rate Automatically calculated by the pump cannot be modified indicates the rate at which the dose is delivered Next Dose Indicates the time at which the next dose will start KVO Rate The KVO Keep Vein Open function allows the delivery of a minimal amount of drug to help maintain catheter patency Reservoir Vol Reservoir volume cassette or bag INTERMITTENT MODE Blue screen ...

Page 15: ...ch medication is delivered Step Duration Delivery time of each step This time is the same for each step and for the initial rate with the exception of the plateau Infusion Duration Time required to deliver the infusion volume Automatically calculated by the pump KVO Rate The KVO Keep Vein Open function allows the delivery of a minimal amount of drug to help maintain catheter patency Reservoir vol ...

Page 16: ... have the option of viewing help screens to help you to solve the problem 1 When an alarm is triggered select Silence to mute the alarm 2 If help screens are available for the alarm Help appears above the right soft key Press this key to view the help screens ALARM HELP SCREENS ...

Page 17: ...e fluid path a closed tubing clamp or a blockage Delivery is paused and will resume if the occlusion is removed This alarm has associated help screens To access them press Silence then Help Reservoir volume low Low Priority Alarm blue screen Depending on your pump s settings an alarm will sound to inform you that the volume in the reservoir bag or cassette is low and that a new bag or cassette mus...

Page 18: ...fusionDuration Max Doses Hr Next Dose Step Duration Plateau Rate InfusionDuration KVO Rate KVO Rate KVO Rate KVO Rate KVO Rate Reservoir Vol Reservoir Vol Reservoir Vol Reservoir Vol Reservoir Vol Start Time Start Time Start Time Start Time This setting does not appear if the PCA dose is zero This setting may not appear depending on the delivery limit method selected This setting appears only if a...

Page 19: ......

Page 20: ... of Smiths Medical The symbol indicates the trademark is registered in the U S Patent and Trademark Office and certain other countries 2016 Smiths Medical All rights reserved IN193563EN 052016 PRODUCT S DESCRIBED MAY NOT BE LICENSED OR AVAILABLE FOR SALE IN CANADA AND OTHER COUNTRIES MPAUCA 1282 Smiths Medical ASD Inc St Paul MN 55112 USA Phone 1 614 210 7300 Toll Free USA 1 800 258 5361 Find your...