User information:
Cleaning and user maintenance shall not be made by children without
supervision
Children of less than 3 years should be kept away unless continuously
supervised
Children aged from 3 years and less than 8 years shall only switch on/off
the appliance provided that it has been placed or installed in its intended
normal operating position and they have been given supervision or
instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children aged from 3 years and less than 8 years shall
not plug in, regulate and clean the appliance or perform user maintenance.
CAUTION — Some parts of this product can become very hot and cause
burns. Particular attention has to be given where children and vulnerable
people are present
.
NOTES
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
2
Fault Finding
7
1. Fan does not run on any switch setting or no
heat output on electric heating mode.
a. Check the power supply is switched ON.
b. Check the fuse in the fused spur.
c. Check the wiring connections at the fused
spur.
2. No heat output on hydronic heating mode.
a. Check the power supply is switched ON.
b. If fitted, ensure the room thermostat is calling
for heat.
c. Balance the central heating system if installed
on the same circuit as panel radiators and
increase the circulating pump speed if required.
d. Increase the boiler water temperature.
3. If the overheat protection has activated on
electric heating mode, manually reset as follows.
a. Switch the power supply OFF at the fused
spur.
b. Wait five minutes for the overheat cut off
switch to reset and then switch the power supply
ON.
In the event of any difficulty, please contact us on 01245 324560.
It will be more helpful if you do remove the product from the central heating system.
Heat Output Performance
It is recommended that the Space Saver model chosen is capable of maintaining the calculated heat
loss at normal heat output (l) enabling the boost setting (ll) to be used for faster heat up.
Heat Output at 80°C
Heat Output at 70°C
Heat Output at 60°C
Heat Output at 50°C
Heat Output at 40°C
Model
Normal
KW
(BTU)
Boost
KW
(BTU)
Normal
KW
(BTU)
Boost
KW
(BTU)
Normal
KW
(BTU)
Boost
KW
(BTU)
Normal
KW
(BTU)
Boost
KW
(BTU)
Normal
KW
(BTU)
Boost
KW
(BTU)
SS5/Dual
1.3
(4400)
1.7
(5800)
1.1
(3800)
1.4
(4700)
0.9
(3100)
1.1
(3800)
0.7
(2400)
0.9
(3100)
0.5
(1700)
0.7
(2400)
Notes:
Dual models include an electric element which in electric heating mode will emit 1kW of heat.
Heat outputs tested in accordance with BS 4856 using entering water temperature. Fan-only option operational only
when central heating system is switched off.
Heat output data for all water temperatures between 80°C and 40°C is available on our website
www.smiths-env.com. Refer to the data sheet in the download section.