background image

Commissioning 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

 
 

 

SS5 /Dual

 

 
The following items should be included in the carton: 

 

 

Product complete with Stainless steel grille (please remove protective film  
before installation) and pre-wired mains cable. 

 

 

Fixing screws (2). 

 

 

One pair flexible installation hoses. 

 

Accessory grilles which fit in place of the standard grille are available in different 
colours and finishes. Please consult the price list for details. In the event of any items 

missing or visible damage, please contact us on 01245 324560. 
 

We would be most grateful if you would leave this Installation & User Guide and the 

Guarantee Registration Card with the owner of the property. 

 

 

Space Saver is primarily intended for installation in 

the space beneath kitchen cupboards behind the 
plinth. However it can also be installed in similar 

applications such as stair risers and other built-in 
furniture. 

 
This Space Saver model must not be installed in a 

bathroom or other high humidity areas. Please 
contact us on 01245 324560 for details of products 

suitable for these applications. 

 
Space Saver is designed for use on standard two-

pipe pumped central heating systems. Pipes are 
15mm and either may be used as flow or return. 

This product is not suitable for one-pipe systems. 
 

Space Saver is classed as a fixed appliance and 
electrical connection should be via a double pole 5A 

fused spur with a minimum contact gap of 3mm. 
The fused spur must not be directly above the 

heater but should be accessible after completion of 
the installation. If the pre-wired mains cable is 

damaged, it must be replaced by either the 
manufacturer, its service agent or similar qualified 

persons. The appliance must be earthed. 

 
Space Saver is fitted with overheat protection. When 

operating in electric heating mode the heater will 

automatically stop in the event of the heating 

element reaching the cut out temperature. 
 

To ensure adequate airflow, a minimum clearance 
of 20mm between the top of the product and any 

shelving is essential. 
 

To avoid the possibility of vibration, this product 
must be installed on a flat even surface. 

 

There must be 

no

 rear access to the product after 

completion of the installation. 

 
To conform with Building Regulations Part L (Part J 

in Scotland), a remote room thermostat (Smith’s 
Part No. RT002) can be used in conjunction with 

this Space Saver fan convector. 
 

The flexible installation hoses supplied are suitable 
for use with either 15mm diameter copper pipe or 

15mm cross-linked polythene barrier pipe to 
BS7291. For all other types of pipe recommend the 

use of compression type fittings. 
 

Please note the guarantee may be invalidated if this 

product is not installed and used in accordance with 
this guide. 

 
 

 

 

 

 

 

 

1. Turn on the electrical supply at the fused spur. 
 

2. Set the upper rocker switch on the fascia grille 
to the right (blue_ and the lower switch to the 

left or right  - the fan should run. 
 

3. Set the upper rocker switch to the left (red) 
and the middle rocker switch to the right (electric 

heating). Heat will start to flow immediately. 
Increasing the fan speed will not increase the 

heat output in the electric heating mode. 
 

4. Turn on the central heating system. 
 

5. Set any room thermostat/s to maximum. 

 

  6. Set the upper rocker switch to the left (red), 

the middle rocker switch to the left (hydronic 

heating) and the lower switch to the left (normal 
output). The fan should run and heat will flow 

within a few minutes. 
 

7. Balance the central heating system if Space 
Saver is installed on the same circuit as panel 

radiators. 
 

8. When the installation is working correctly, 
remember to reset any thermostat/s to there 

normal setting. 

 

5. Position heater, making sure the flexible 

hoses are not kinked and the electrical 
cable is not snagged. 

 

6. Fix assembled heater to plinth using fixing 

screw holes located at either ends of grille. 

Grille to plinth securing screws 

HOSE 

BEND RADIUS 

60mm MIN 

Plinth 

Electrical Cable 