Commissioning
6
SS5 /Dual
The following items should be included in the carton:
Product complete with Stainless steel grille (please remove protective film
before installation) and pre-wired mains cable.
Fixing screws (2).
One pair flexible installation hoses.
Accessory grilles which fit in place of the standard grille are available in different
colours and finishes. Please consult the price list for details. In the event of any items
missing or visible damage, please contact us on 01245 324560.
We would be most grateful if you would leave this Installation & User Guide and the
Guarantee Registration Card with the owner of the property.
Space Saver is primarily intended for installation in
the space beneath kitchen cupboards behind the
plinth. However it can also be installed in similar
applications such as stair risers and other built-in
furniture.
This Space Saver model must not be installed in a
bathroom or other high humidity areas. Please
contact us on 01245 324560 for details of products
suitable for these applications.
Space Saver is designed for use on standard two-
pipe pumped central heating systems. Pipes are
15mm and either may be used as flow or return.
This product is not suitable for one-pipe systems.
Space Saver is classed as a fixed appliance and
electrical connection should be via a double pole 5A
fused spur with a minimum contact gap of 3mm.
The fused spur must not be directly above the
heater but should be accessible after completion of
the installation. If the pre-wired mains cable is
damaged, it must be replaced by either the
manufacturer, its service agent or similar qualified
persons. The appliance must be earthed.
Space Saver is fitted with overheat protection. When
operating in electric heating mode the heater will
automatically stop in the event of the heating
element reaching the cut out temperature.
To ensure adequate airflow, a minimum clearance
of 20mm between the top of the product and any
shelving is essential.
To avoid the possibility of vibration, this product
must be installed on a flat even surface.
There must be
no
rear access to the product after
completion of the installation.
To conform with Building Regulations Part L (Part J
in Scotland), a remote room thermostat (Smith’s
Part No. RT002) can be used in conjunction with
this Space Saver fan convector.
The flexible installation hoses supplied are suitable
for use with either 15mm diameter copper pipe or
15mm cross-linked polythene barrier pipe to
BS7291. For all other types of pipe recommend the
use of compression type fittings.
Please note the guarantee may be invalidated if this
product is not installed and used in accordance with
this guide.
3
1. Turn on the electrical supply at the fused spur.
2. Set the upper rocker switch on the fascia grille
to the right (blue_ and the lower switch to the
left or right - the fan should run.
3. Set the upper rocker switch to the left (red)
and the middle rocker switch to the right (electric
heating). Heat will start to flow immediately.
Increasing the fan speed will not increase the
heat output in the electric heating mode.
4. Turn on the central heating system.
5. Set any room thermostat/s to maximum.
6. Set the upper rocker switch to the left (red),
the middle rocker switch to the left (hydronic
heating) and the lower switch to the left (normal
output). The fan should run and heat will flow
within a few minutes.
7. Balance the central heating system if Space
Saver is installed on the same circuit as panel
radiators.
8. When the installation is working correctly,
remember to reset any thermostat/s to there
normal setting.
5. Position heater, making sure the flexible
hoses are not kinked and the electrical
cable is not snagged.
6. Fix assembled heater to plinth using fixing
screw holes located at either ends of grille.
Grille to plinth securing screws
HOSE
BEND RADIUS
60mm MIN
Plinth
Electrical Cable