INTRODUCTION 

 

In the event of items missing or visible damage please contact us on 01245 324560.  

 

This heating appliance is intended for mounting on a wall at low level. The minimum 
recommended  installation  height  is  150cm  (6  inches)  from  the  floor.    There  is  no 
clearance required on either side of the heater. 

 

This heater must not be used in bathrooms or other high humidity areas.  

 

Ecovector™  is  designed  for  use  on  standard  two-pipe  pumped  central  heating 
systems  where the system hot water is generated from either a boiler or renewable 
sources. This product is not suitable for one-pipe heating systems.

 

Pipe connections 

are 15mm. 

 

We  recommend  the  use  of  full  flow  isolating  valves.    These  valves  should  be 
accessible after completion of the installation. 

 

Ecovector™ is classified as a fixed appliance and electrical connection should be via 
a double pole 3A fused  spur. The fused spur must not be directly above the heater 
but should be accessible after completion of the installation.  If the pre-wired mains 
cable  is  damaged,  it  must  be  replaced  by  the  manufacturer,  its  service  agent  or 
similarly qualified persons. The appliance must be earthed. 

 

To avoid possibility of vibration, this product must be installed on a flat, even surface. 

 

To  comply  with  Building  Regulations  Part  L  (Part  J  in  Scotland)  this  heater  is  fitted 
and controlled by an integral room thermostat

 

 

Please  note  the  guarantee  may  be  invalidated  if  this  product  is  not  installed 
and used in accordance with this guide. 

 

MOUNTING THE UNIT 

 

Remove  the  EZ  hanger  from  the  back  of  the  heater.  Remove  screws  from  the 
underside of the front panel, carefully lift up and remove

 

  

                     

 

 

 

 
Ecovector™  includes  a  selectable  low  temperature  thermostat  that  prevents  the 
fan(s)  operating  until  the  central  heating  system  water  passing  through  the  heat 
exchanger reaches a set temperature. 

 

Heating 

 

Ensure  your  central  heating  is  ON,  the  heat  output  switch  set  to  Low  (I)  and  the 
thermostat set to the required position (position 3 is approximately 20°C). 

 

If you require a faster warm up set the heat output switch to High (II) 

 

 

 

 
 

 
 

 

 