FAULT FINDING 

 

Fan does not run on any switch setting 

 

 

Check the power source is switched ON 

 

Check fuse in the fused spur 

 

Check wiring connections at the fused spur 

 

No heat output on settings I and II 

 

 

Check the power supply is switched ON 

 

Ensure the room thermostat is calling for heat 

 

Check the heat source switch is in the correct mode 

 

Balance  the  central  heating  system if installed  on  the same  circuit  as  panel 
radiators and increase the circulating pump speed if required. 

 

Increase the heat source water temperature 

 

In the event of difficulty please contact us on 01245 324560.  It will be more helpful if 
you do not remove the product from the central heating system. 

 

We would be most grateful if you would leave this installation & operation guide and 
the guarantee registration card with the owner of the property. 

 

USER GUIDE 

 

Your  product  is  covered  by  a  free  5-year  parts  and  labour  guarantee;  please 
complete  and  return  the  Guarantee  Registration  Card  to  us  as  soon  as  possible  to 
ensure that should you require assistance, we can help you quickly and efficiently. 

 

Your Ecovector™ is designed to operate as part of your central heating system in the 
same  way  as  a  panel  radiator.    Providing  you  leave  the  heater  switches  in  their 
normal  operating  positions  it  will  switch  on  and  off  automatically  with  you  central 
heating system. 

 

Heat from your central heating system passes through a heat exchanger transferring 
its  heat  to  the  aluminium  fins,  room  air  is  drawn  in  the  top  grille  and  heated  as  it 
passes through the heat exchanger before being gently expelled back into the room 
at floor level.   

 

 
 
 
 
 
 
 
 
 
 

 
Fix the EZ hanger to the wall, position the heater on the EZ hanger and secure to the 
wall at the five fixing points. 

 

 
 

 

PIPE WORK 

 

We  recommend  the  use  of  full  flow  isolating  valves.    These  valves  should  be 
accessible after completion of the installation.  Pipe work can be brought out from the 
heater  directly  or  through  the  rear  chassis.  A  lower  panel  blanking  plate  is  packed 
and supplied with the heater if the latter option is used (to fit this remove the 3 screws 
from the fitted slotted pipe access panel and replace with the blanking plate). 

 

Connect  the  heating  system flow  and  return  pipes  to  the  heater  pipe  work.    Do  not 
use  soldered  fittings  to  the  heater  pipe  work  as  he  heat  generated  could  damage 
internal wiring and components. The pipe nearest the front of the heater is the supply 
flow and the pipe nearest the chassis is the return.  

 

Check for water leaks.  Remove any trapped air from the system via the vent valve 
on the top left hand side of the heat exchanger.  Do not over tighten the air vent 

  

 

 

 
 