![Smiths detection eqo Operating Instructions Manual Download Page 58](http://html.mh-extra.com/html/smiths-detection/eqo/eqo_operating-instructions-manual_1305987058.webp)
Operation
Evaluation of the image sequence
After reviewing an image sequence the remote operator has to
evaluate the image data.
In case, that no anomaly has been identified, he presses the clear
key
on the function key panel ( 16).
At the local station's main screen the clear-button is highlighted,
and the local operator station returns to ready state (see Fig. 78).
In case, that remote operator identifies an anomaly, he presses the
suspect key
and communicates the position of the anomaly via
an audio channel to the local operator
Important!
In the case where an anomaly has been identified, any
site specific standard operating procedure (SOP) should
be followed. For example a targeted pat-down should be
performed as indicated by the position of the anomaly
on the image.
After the SOP has been accomplished the remote operator has to
press the clear key
to get the local station back to the “Ready”-
state.
Initiate a Re-Scan
In case, that the image sequence has been to short or the quality of
the collected image sequence is insufficient the remote operator
has the possibility to initiate a Re-Scan by pressing
V
.
The Re-Scan is available anytime during the remote reviewing ses-
sion. If the re-scan is pressed it has the effect of clearing the scan
on the local station but it does not report a decision i.e. “CLEAR” or
“SEARCH”.
The Re-Scan has the effect of a new scan, but the passenger count
is not incremented.
95591706 11/02/2010 © smiths detection proprietary information
52
Fig. 78: Local station in ready state
Fig. 79: Local station's main screen - “search”
button active
Summary of Contents for eqo
Page 6: ...Table of contents 95591706 11 02 2010 smiths detection proprietary information IV ...
Page 12: ...General information 95591706 11 02 2010 smiths detection proprietary information 6 ...
Page 44: ...Safety instructions 95591706 11 02 2010 smiths detection proprietary information 38 ...
Page 54: ...Start up 95591706 11 02 2010 smiths detection proprietary information 48 ...
Page 60: ...Operation 95591706 11 02 2010 smiths detection proprietary information 54 ...
Page 68: ...Annex A 95591706 11 02 2010 smiths detection proprietary information 62 ...
Page 70: ......