Setup
14
3A5578D
Menu Screen #5 - Error Codes
Displays the most recent error code and the total number of
times that error has occurred. Cycle through previous error
codes using Up/Down Buttons.
Error Codes
E04: High Voltage
E05: High Motor Current
E08: Low Voltage
E09: Hall Sensor Error
E12: High Current (short circuit)
E31: Home Button Error
E32: Zero Button Error
E33: Cut Depth Button Error
E34: Up Button Error
E35: Down Button Error
To clear an error code that appears while on the Run
Screen:
1. Turn DCS Power Switch OFF.
2. Address/Fix the issue.
3. Turn DCS Power Switch ON.
NOTE:
See Repair Manual for more information on Error
Codes and Troubleshooting.
Summary of Contents for SPS10
Page 52: ...Parts 52 3A5578D NOTES...
Page 56: ...Parts 56 3A5578D NOTES...
Page 57: ...Parts 3A5578D 57 Drive Assembly SPS10 SPS10 DCS Ref Torque 160 170 in lb 18 1 19 2 N m 1 1 1 1...
Page 61: ...DCS Control Box 18A790 3A5578D 61 DCS Control Box 18A790 SPS10 only...
Page 63: ...Wiring Diagram 3A5578D 63 Wiring Diagram DCS System 17Y99 17Y23 18A79...
Page 64: ...Wiring Diagram 64 3A5578D DCS Control Box Powers Display...