Charging the Pump Internal Battery

1.  In a dry, clean location insert the Charger Plug 

into a standard electrical wall outlet. On the 
end of the Pump handle (E), remove the rubber 
Cover (C) to expose the Charging Port (D). Plug 
the Charger Cable into the Charging Port on 
the Pump. The Light (B) on the top of the Pump 
should start flashing green.
a.  The Pump cannot be operated while charging. 

The Pump must be disconnected from the 
Charger to permit further use.

b.  If the Light on the Pump flashes red, the 

Battery is too hot to be safely charged. This 
can happen when the Battery is used heavily 
in very hot weather or if the Battery is stored 
in a very hot location (such as in an enclosed 
vehicle or storage unit during very hot 
weather). If this happens the Battery must be 
allowed to cool before it can be charged.

c.  If the Light on the Pump flashes red and green 

alternately, this means the Battery has been 
damaged and cannot be charged within the 
safe charging time limit. The internal Battery 
cannot be serviced, so the Pump must be 
replaced.

10.  Ensure the Pump and Charger are placed 

where they will not be exposed to liquids, falls or 
other sources of damage for the duration of the 
charging period.

11.  When charging is complete the Light will 

remain green and stay on constantly. Charging 
time will vary depending on Battery condition at 
the start of charging. Charging time should not 
exceed 3 hours.

12.  Remove the Charger Cable from the Pump 

once charging is complete. Pumps should not be 
connected to the Charger during long periods of 
storage. To ensure optimal Battery life the Pump 
should be charged at least once every 3 months 
when not in use.

13.  Reinsert the rubber Cover into the Charging 

Port to protect it.

14.  Unplug the Charger from the electrical wall 

outlet when not in use.

D

C

Filling the Sprayer

 

DANGER:

 RISK OF DEATH, PERSONAL INJURY 

AND/OR PROPERTY DAMAGE FROM IMPROPER 

CHEMICAL USE OR MIXTURE. Never use flammable 

or combustible liquids, caustics, acids, or hot water 

in this Sprayer. Spraying flammable or combustible 

liquids can create combustible fumes that could 

be ignited by the electrical system in the Sprayer, 

causing an explosion. Always refer to chemical 

manufacturer instructions for proper mixture. Always 

wear appropriate personal protection equipment 

as instructed by chemical manufacturer when 

using, preparing, handling, spraying, or disposing of 

chemicals. This includes at least goggles, gloves, and 

protective clothing.

 

WARNING:

 Inspect the sprayer, hose, shut-off, wand, 

and all connections for damage before each use. 

A damaged or loose hose connection can result in 

unintended exposure to the pressurized chemicals, 

resulting in serious injury or property damage.

 

WARNING:

 RISK OF DAMAGE TO INTERNAL 

COMPONENTS. Use of chemicals other than water 

based or water soluble solutions may damage the 

Sprayer and will void the warranty. 

1.  Ensure that the Pump is turned OFF (Light is 

OFF).

2.  Pull up on the knob of the Pressure Release Valve 

(G) until all the pressure is released from the tank.

3.  Turn the Pump handle (E) counterclockwise to 

remove the pump.

4.  Fill the Tank to the desired level. See volume 

gradation markings markings on side of Tank. 

(Always refer to chemical manufacturer for 

proper mixture).

5.  Install the Pump into the Tank opening and turn 

clockwise until tightly sealed against the Tank.

G

E

E

ENGLISH

Summary of Contents for 190728

Page 1: ...fgi com 23 Garden St New York Mills NY 13417 Do not return this product to the store For help information or parts contact WARNING Read and fully understand manual before using this product Failure to...

Page 2: ...LY 4 Assembling the Hose to the Tank 4 Assemble Hose Extension Shut Off Nozzle 5 OPERATION 5 Charging the Pump Internal Battery 6 Filling the Sprayer 6 Powering On and Spraying 7 CLEANING 7 Cleaning S...

Page 3: ...urer and or refer to the chemical Safety Data Sheet SDS of the chemical being used This includes at least goggles gloves and protective clothing Failure to use appropriate PPE could result in chemical...

Page 4: ...lly it is not expected to run continuously The Pump will pressurize the air inside the Tank then turn off and let the air pressure do the work of spraying out the fluid As the fluid is sprayed out the...

Page 5: ...ipment PPE as recommended by the chemical manufacturer and or refer to the chemical Safety Data Sheet SDS of the chemical being used This includes at least goggles gloves and protective clothing WARNI...

Page 6: ...ttery life the Pump should be charged at least once every 3 months when not in use 13 Reinsert the rubber Cover into the Charging Port to protect it 14 Unplug the Charger from the electrical wall outl...

Page 7: ...from the sprayer prior to cleaning Disassembly of a sprayer that is still pressurized may result in the high speed ejection of components WARNING RISK OF PERSONAL INJURY DUE TO CHEMICAL EXPOSURE Alway...

Page 8: ...here freezing temperatures below 32 F 0 C will occur Allowing water to freeze inside the Sprayer may damage the Pump Seals Shutoff or other components and void the Sprayer warranty 32 To ensure optima...

Page 9: ...nt does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more...

Page 10: ...zzle clogged Clean Nozzle See Nozzle Maintenance Pump is not tightened to Tank leaks at Seal Tighten Pump to Tank Sprayer turns on but only sprays at low pressure Tank not yet pressurized Allow time f...

Page 11: ...Pump Charger plugged into outlet Check that outlet is functioning No lights illuminated on Pump Charger plugged into outlet outlet functioning Replace Charger Red light continues flashing on Pump Bat...

Page 12: ...ension Assy 18 Brass 5 182641 Seal Viton Extension S S 2 each required 6 183296 Nut Brass Extension 7 184741 Hose Assy NPT Tank Barb Nylon Rubber 0 313ID x 50L Black 8 184175 Pump Charger Kit US PZ 9...

Page 13: ...www thefountainheadgroup com...

Page 14: ...Mills NY 13417 Ne pas retourner ce pulv risateur au magasin Si vous avez besoin d aide de renseignements ou de pi ces appelez au AVERTISSEMENT Read and fully understand manual before using this produc...

Page 15: ...er le Boyau au R servoir 18 Assembler le boyau la rallonge le dispositif d arr t et la buse 19 FONCTIONNEMENT 19 Chargement de la pile interne de la pompe 20 Remplir le pulv risateur 20 Alimentation e...

Page 16: ...tiquette du fabricant des substances chimiques qui seront utilis es dans ce pulv risateur Utiliser l quipement de protection individuelle EPI appropri comme recommand par le fabricant de la substance...

Page 17: ...le fluide travers le boyau jusqu la buse pour tre pulv ris Puisque la pompe lectrique PumpZero fonctionne par la mise sous pression de l air l int rieur du r servoir il est important de refermer herm...

Page 18: ...la substance chimique ou consulter la fiche signal tique de la substance chimique utilis e L EPI comprend au moins des lunettes de s curit des gants et des v tements de protection AVERTISSEMENT Pour r...

Page 19: ...le de caoutchouc sur le port de chargement pour le prot ger 6 D brancher le chargeur de la prise de courant murale lorsque vous ne l utilisez pas D C Remplir le pulv risateur AVERTISSEMENT RISQUE DE M...

Page 20: ...ng Disassembly of a sprayer that is still pressurized may result in the high speed ejection of components AVERTISSEMENT RISQUE DE BLESSURE R SULTANT DE L EXPOSITION AUX PRODUITS CHIMIQUES Toujours por...

Page 21: ...temp ratures peuvent atteindre le point de cong lation moins de 32 F 0 C Si le liquide l int rieur du pulv risateur g le il est possible d endommager la pompe les joints d tanch it le dispositif d ar...

Page 22: ...nt produit des interf rences qui nuisent une r ception radio ou t l visuelle ce qui peut tre d termin en teignant et en allumant l appareil l utilisateur est invit corriger la situation par l un ou l...

Page 23: ...teur s allume on entend le ronflement de la pompe mais ne pulv rise pas Le r servoir est vide Ajouter du liquide dans le r servoir Voir Remplissage du r servoir Le r servoir est vide Nettoyer le dispo...

Page 24: ...pompe La buse est partiellement obstru e Nettoyer la buse Voir Entretien de la buse La buse est endommag e Remplacer la buse Le dispositif d arr t est obstru Nettoyer le dispositif d arr t Voir Entre...

Page 25: ...83296 crou rallonge en laiton 7 184741 Ensemble pour boyau raccord cannel avec filetage NPT pour r servoir nylon et caoutchouc 0 313ID x 50L noir 8 184175 Trousse d entretien pour dispositif d arr t 1...

Page 26: ...www thefountainheadgroup com...

Page 27: ...NY 13417 No devuelva este atomizador a la tienda Para obtener ayuda informaci n o piezas llame al ADVERTENCIA Lea y comprenda completamente el manual antes de usar este producto El incumplimiento de...

Page 28: ...ue 31 Ensamble la manguera la extensi n la v lvula de paso y la boquilla 32 FUNCIONAMIENTO 32 Carga de la bater a interna de la bomba 33 Llenado del atomizador 33 Encendido y rociado 34 LIMPIEZA 34 Li...

Page 29: ...de protecci n personal EPP adecuado seg n las recomendaciones del fabricante del producto qu mico y o consulte la hoja de datos de seguridad SDS del producto qu mico que se utilizar Esto incluye al me...

Page 30: ...y desactive por s misma peri dicamente no se espera que se ejecute continuamente La bomba presurizar el aire dentro del tanque luego se desactivar y dejar que la presi n del aire haga el trabajo de r...

Page 31: ...nal EPP adecuado seg n las recomendaciones del fabricante del producto qu mico y o consulte la hoja de datos de seguridad SDS del producto qu mico que se utilizar Esto incluye al menos gafas guantes y...

Page 32: ...s cuando no est en uso 5 Reinserte la cubierta de goma en el puerto de carga para protegerlo 6 Desconecte el cargador del tomacorriente el ctrico de la pared cuando no est en uso D C Llenado del atomi...

Page 33: ...est presurizado puede provocar la expulsi n de componentes a alta velocidad ADVERTENCIA RIESGO DE LESIONES PERSONALES DEBIDO A EXPOSICI N QU MICA Siempre use equipo de protecci n personal adecuado seg...

Page 34: ...emperaturas g lidas debajo de 32 F 0 C Permitir que el agua se congele dentro del atomizador puede causar da os a la bomba los sellos la v lvula de cierre u otros componentes y anular la garant a del...

Page 35: ...rferencias perjudiciales en la recepci n de radio o televisi n lo cual puede determinarse al encender y apagar el equipo se recomienda al usuario que intente corregir la interferencia mediante una o m...

Page 36: ...bomba pero no roc a No hay l quido en el tanque Agregue l quido al tanque Ver Llenado del atomizador La v lvula de cierre est obstruida Limpie la v lvula de cierre Ver Mantenimiento de la v lvula de c...

Page 37: ...la boquilla La v lvula de cierre est obstruida Limpie la v lvula de cierre Ver Mantenimiento de la v lvula de cierre La bater a no carga El cargador no est conectado al tomacorriente Conecte el carga...

Page 38: ...Sello Viton extensi n S S se requieren 2 en cada sitio 6 183296 Tuerca extensi n de lat n 7 184741 Conjuntodemanguera NPTyestriadaparatanque nylonycaucho D I 0 313x50L negra 8 184175 Kit de v lvula d...

Page 39: ...www thefountainheadgroup com...