Code
Display Message
Description
Cleared By
U01
LR-24 Tilted Too Far
LR-24 has been tilted from verti-
cal beyond safe limits.
Pole Switch
U02
Immersion Detected
LR-24 has been immersed in
water.
Power On/Off
U03
Low Output Current
Electrodes may be out of the
water.
Pole Switch
U04
Pole Switch on at Power-up.
Pole switch engaged when
power was turned on.
Pole Switch
U05
Voltage detected on output
A voltage above 30V is seen on
the electrodes when the output
is turned off, likely due to other
LR-24s.
Automatic
P01
Peak Amps Overload
Electrodes likely have been
shorted.
Pole Switch
P02
Low Battery Voltage
Battery has been drained, needs
recharging.
Power On/Off
P03
Over Temperature
LR-24 has gotten too hot, let
cool.
Pole Switch
P04
High Battery Current
Too much power from battery,
reduce output voltage or duty
cycle.
Pole Switch
P05
High Output Current
Average output current above 4
Amps, reduce output voltage or
duty cycle.
Pole Switch
P06
Inverter Overload
LR-24 unable to maintain re-
quested output voltage into the
current load. A lower output
voltage will be suggested to help
prevent failure. May require sev-
eral attempts to find a voltage
that will work.
Press Enter Key on Keypad.
S01
Low Battery Current
Measurement system failure,
send in for repair.
Power On/Off
S02
50V Out Of Range
Voltage regulator failure, send in
for repair.
Power On/Off
S03
150V Out Of Range
Voltage regulator failure, send in
for repair.
Power On/Off
S04
300V Out Of Range
Voltage regulator failure, send in
for repair.
Power On/Off
S05
500V Out Of Range
Voltage regulator failure, send in
for repair.
Power On/Off
S06
800V Out Of Range
Voltage regulator failure, send in
for repair.
Power On/Off
S07
Safety Relay Failure
The output safety relay is open,
send in for repair.
Power On/Off
S08
No IGBT Output
The output switch is open, send
in for repair.
Power On/Off
S09
IGBT HV Breakdown
The output switch fails at high
voltage, send in for repair.
Power On/Off
S10
Output IGBT Failure
The output switch has shorted,
send in for repair.
Power On/Off
S11
Memory Test Failure
The microprocessor has detected
a failure and may not be reliable.
Send in for repair.
Power On/Off
---
No Error
Place holder in history, not an
error.
N/A