IR lamp control module - HELCON 11XX series -
Installation, use and maintenance manual - EN
Ver. 1.02
13
5.2 Mechanical assembly
5.2.1 Positioning and fixing
The HELCON series modules are suitable for “exposed” mounting; to ensure effective heat dissipation, it is
necessary to mount them in a vertical position, using the fixing holes provided for this purpose.
The following image shows the dislocation of the upper fixing holes, which is realized by means of a metal insert
with metric thread M6 (MA pitch). The stem portion of the screw entering the insert must not exceed 14 mm
(recommended value 12 mm). Use screws with a strength class of 8.8 or higher; the recommended tightening
torque is 10 Nm ± 10%. In the presence of vibrations, we recommend the use of anti-unscrew washers (for
example Grover or Belleville), or use medium braid compound (Loctite 243 or equivalent).
The following image shows the dislocation of the lower fixing holes, made within two metal support ears. The
fixation of the device to the support can be carried out by means of through screws fitted with a locknut. As
regards the choice of suitable screws, please refer to the above.
Upper side view (TOP)