COSMOS DRIVER SERIES 3000 - USE AND MAINTENANCE MANUAL
7.2.6.2
Models for asynchronous motor
Menu
Entry
Lev
.
Description
1.3
>CONTROL
-
This section includes the controller setting and the
parameters of the driver control system.
1.3.1
CONTROLLER
3
It determines the driver control mode.
Options=FLxIO, Service
1.3.2
ACC RAMP [Hz/s]
2
Frequency ramps acceleration value
1.3.3
DEC RAMP [Hz/s]
2
Frequency ramps deceleration value
1.3.4
FREQ MIN
[Hz]
2
Minimum frequency that can be generated by the
driver, expressed in hertz.
Together with the value VRMS MIN, it determines
one of the points defining the line V/f that
determines the voltage generated depending on the
required frequency.
1.3.5
FREQ NOM
[Hz]
2
Rated frequency in hertz.
Together with the value VRMS NOM, it determines
one of the points defining the line V/f that
determines the voltage generated depending on the
required frequency.
1.3.6
FREQ MAX
[Hz]
2
Maximum frequency that can be generated by the
driver, expressed in hertz.
By setting higher references, the driver generates
this frequency.
1.3.7
VRMS MIV
[V]
2
rms voltage, expressed in volt, at minimum
frequency. Together with the value FREQ MIN, it
determines one of the points defining the line V/f
that determines the voltage generated depending on
the required frequency.
1.3.8
VRMS NOM
[V]
2
Rms voltage, expressed in volt, at rated frequency.
Together with the value FREQ NOM, it determines
one of the points defining the line V/f that
determines the voltage generated depending on the
required frequency.
Ver. 1.07
Pag. 65